P.S : As I said before, make sure you are replacing the STANDBY SUP, not the active one (unless NSF is configured for your IGPs, etc...).
Y. 2010/3/25 Youssef Bengelloun-Zahr <[email protected]> > Also, check out this : > > > http://www.cisco.com/en/US/products/hw/switches/ps708/products_configuration_example09186a008086ed2e.shtml > > Y. > > > > 2010/3/25 Youssef Bengelloun-Zahr <[email protected]> > > Hello John, >> >> Based on your posting, the sup in slot 5 is in STANDBY state, so no >> worries to have :-) >> >> FYI : >> >> >> https://supportforums.cisco.com/docs/DOC-4068/version/1;jsessionid=667B4E9940D21005AC46FD72F7A602B9.node0 >> >> Good luck ! >> >> Y. >> >> >> >> 2010/3/25 John Smith <[email protected]> >> >> We have a 6500 Switch in our network with two SUP720 engines running in >>> SSO mode; one engine is Active and the other is in Standby Hot. The Sup >>> engines are in slot 5 and slot 6. We need to replace the card in Slot 5. >>> >>> Does anyone have a step by step procedure and/or web link on how to >>> replace the redundant supervisor card without rebooting the chassis. >>> >>> Any/all help is much appreciated. Thank you. >>> >>> We have the following config for the supervisors. >>> >>> ! >>> redundancy >>> mode sso >>> main-cpu >>> auto-sync running-config >>> auto-sync standard >>> ! >>> >>> Switch#show redundancy >>> Redundant System Information : >>> ------------------------------ >>> Available system uptime = 2 year, 7 weeks, 3 days, 8 hours, 33 >>> minutes >>> Switchovers system experienced = 0 >>> Standby failures = 0 >>> Last switchover reason = none >>> >>> Hardware Mode = Duplex >>> Configured Redundancy Mode = sso >>> Operating Redundancy Mode = sso >>> Maintenance Mode = Disabled >>> Communications = Up >>> >>> Current Processor Information : >>> ------------------------------- >>> Active Location = slot 6 >>> Current Software state = ACTIVE >>> Uptime in current state = 2 year, 7 weeks, 3 days, 8 hours, 32 >>> minutes >>> Image Version = Cisco Internetwork Operating System >>> Software >>> IOS (tm) s72033_rp Software (s72033_rp-ADVIPSERVICESK9_WAN-M), Version >>> 12.2(18)SXF7, RELEASE SOFTWARE (fc1) >>> Technical Support: http://www.cisco.com/techsupport >>> Copyright (c) 1986-2006 by cisco Systems, Inc. >>> Compiled Thu 23-Nov-06 06:00 by kellythw >>> BOOT = disk0:,1; >>> CONFIG_FILE = >>> BOOTLDR = >>> Configuration register = 0x2102 >>> >>> Peer Processor Information : >>> ---------------------------- >>> Standby Location = slot 5 >>> Current Software state = STANDBY HOT >>> Uptime in current state = 2 year, 7 weeks, 3 days, 8 hours, 32 >>> minutes >>> Image Version = Cisco Internetwork Operating System >>> Software >>> IOS (tm) s72033_rp Software (s72033_rp-ADVIPSERVICESK9_WAN-M), Version >>> 12.2(18)SXF7, RELEASE SOFTWARE (fc1) >>> Technical Support: http://www.cisco.com/techsupport >>> Copyright (c) 1986-2006 by cisco Systems, Inc. >>> Compiled Thu 23-Nov-06 06:00 by kellythw >>> BOOT = disk0:,1; >>> CONFIG_FILE = >>> BOOTLDR = >>> Configuration register = 0x2102 >>> >>> >>> Thanks! >>> -John- >>> >>> >>> >>> >>> _______________________________________________ >>> cisco-nsp mailing list [email protected] >>> https://puck.nether.net/mailman/listinfo/cisco-nsp >>> archive at http://puck.nether.net/pipermail/cisco-nsp/ >>> >> >> >> >> -- >> Youssef BENGELLOUN-ZAHR ……………………………………………… >> Ingénieur Réseaux et Télécoms >> >> >> Technopole de l'Aube en Champagne - BP 601 - 10901 TROYES Cedex 9 >> Agence Paris : 6, rue Charles Floquet - 92120 MONTROUGE >> Tel +33 (0) 825 000 720 >> Tel. direct +33 (0) 1 77 35 59 14 >> Tel. portable +33 (0) 6 22 42 63 80 >> Email [email protected] >> ……………………………………………………………………………….....www.720.fr >> >> > > > -- > Youssef BENGELLOUN-ZAHR ……………………………………………… > Ingénieur Réseaux et Télécoms > > > Technopole de l'Aube en Champagne - BP 601 - 10901 TROYES Cedex 9 > Agence Paris : 6, rue Charles Floquet - 92120 MONTROUGE > Tel +33 (0) 825 000 720 > Tel. direct +33 (0) 1 77 35 59 14 > Tel. portable +33 (0) 6 22 42 63 80 > Email [email protected] > ……………………………………………………………………………….....www.720.fr > > -- Youssef BENGELLOUN-ZAHR ……………………………………………… Ingénieur Réseaux et Télécoms Technopole de l'Aube en Champagne - BP 601 - 10901 TROYES Cedex 9 Agence Paris : 6, rue Charles Floquet - 92120 MONTROUGE Tel +33 (0) 825 000 720 Tel. direct +33 (0) 1 77 35 59 14 Tel. portable +33 (0) 6 22 42 63 80 Email [email protected] ……………………………………………………………………………….....www.720.fr _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/