Greetings, To all who responded to my query ... Thank you for your responses. I appreciate it. I have couple more questions. Do I need to do anything with the SSO or Redundancy config before I remove the bad Sup module in Slot 5 and insert in the new module? The new module is coming from Cisco, so I have no idea what IOS it will have on it. We do not have a spare chassis to stage the new module coming from Cisco.
Will the IOS and Config automatically sync with the Active module in slot 6 when I insert the new/replacement module in slot 5. Thanks again for all your help. I very much appreciate it. Thanks! -John- --- On Thu, 3/25/10, Youssef Bengelloun-Zahr <[email protected]> wrote: From: Youssef Bengelloun-Zahr <[email protected]> Subject: Re: [c-nsp] Replacing redundant Sup720 on Catalyst 6500 To: "John Smith" <[email protected]> Cc: [email protected] Date: Thursday, March 25, 2010, 4:54 PM P.S : As I said before, make sure you are replacing the STANDBY SUP, not the active one (unless NSF is configured for your IGPs, etc...). Y. 2010/3/25 Youssef Bengelloun-Zahr <[email protected]> Also, check out this : http://www.cisco.com/en/US/products/hw/switches/ps708/products_configuration_example09186a008086ed2e.shtml Y. 2010/3/25 Youssef Bengelloun-Zahr <[email protected]> Hello John, Based on your posting, the sup in slot 5 is in STANDBY state, so no worries to have :-) FYI : https://supportforums.cisco.com/docs/DOC-4068/version/1;jsessionid=667B4E9940D21005AC46FD72F7A602B9.node0 Good luck ! Y. 2010/3/25 John Smith <[email protected]> We have a 6500 Switch in our network with two SUP720 engines running in SSO mode; one engine is Active and the other is in Standby Hot. The Sup engines are in slot 5 and slot 6. We need to replace the card in Slot 5. Does anyone have a step by step procedure and/or web link on how to replace the redundant supervisor card without rebooting the chassis. Any/all help is much appreciated. Thank you. We have the following config for the supervisors. ! redundancy mode sso main-cpu auto-sync running-config auto-sync standard ! Switch#show redundancy Redundant System Information : ------------------------------ Available system uptime = 2 year, 7 weeks, 3 days, 8 hours, 33 minutes Switchovers system experienced = 0 Standby failures = 0 Last switchover reason = none Hardware Mode = Duplex Configured Redundancy Mode = sso Operating Redundancy Mode = sso Maintenance Mode = Disabled Communications = Up Current Processor Information : ------------------------------- Active Location = slot 6 Current Software state = ACTIVE Uptime in current state = 2 year, 7 weeks, 3 days, 8 hours, 32 minutes Image Version = Cisco Internetwork Operating System Software IOS (tm) s72033_rp Software (s72033_rp-ADVIPSERVICESK9_WAN-M), Version 12.2(18)SXF7, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Thu 23-Nov-06 06:00 by kellythw BOOT = disk0:,1; CONFIG_FILE = BOOTLDR = Configuration register = 0x2102 Peer Processor Information : ---------------------------- Standby Location = slot 5 Current Software state = STANDBY HOT Uptime in current state = 2 year, 7 weeks, 3 days, 8 hours, 32 minutes Image Version = Cisco Internetwork Operating System Software IOS (tm) s72033_rp Software (s72033_rp-ADVIPSERVICESK9_WAN-M), Version 12.2(18)SXF7, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Thu 23-Nov-06 06:00 by kellythw BOOT = disk0:,1; CONFIG_FILE = BOOTLDR = Configuration register = 0x2102 Thanks! -John- _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/ -- Youssef BENGELLOUN-ZAHR ……………………………………………… Ingénieur Réseaux et Télécoms Technopole de l'Aube en Champagne - BP 601 - 10901 TROYES Cedex 9 Agence Paris : 6, rue Charles Floquet - 92120 MONTROUGE Tel +33 (0) 825 000 720 Tel. direct +33 (0) 1 77 35 59 14 Tel. portable +33 (0) 6 22 42 63 80 Email [email protected] ……………………………………………………………………………….....www.720.fr -- Youssef BENGELLOUN-ZAHR ……………………………………………… Ingénieur Réseaux et Télécoms Technopole de l'Aube en Champagne - BP 601 - 10901 TROYES Cedex 9 Agence Paris : 6, rue Charles Floquet - 92120 MONTROUGE Tel +33 (0) 825 000 720 Tel. direct +33 (0) 1 77 35 59 14 Tel. portable +33 (0) 6 22 42 63 80 Email [email protected] ……………………………………………………………………………….....www.720.fr -- Youssef BENGELLOUN-ZAHR ……………………………………………… Ingénieur Réseaux et Télécoms Technopole de l'Aube en Champagne - BP 601 - 10901 TROYES Cedex 9 Agence Paris : 6, rue Charles Floquet - 92120 MONTROUGE Tel +33 (0) 825 000 720 Tel. direct +33 (0) 1 77 35 59 14 Tel. portable +33 (0) 6 22 42 63 80 Email [email protected] ……………………………………………………………………………….....www.720.fr _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/