You have probably selected AFSK mode, not DataA.  Hold the "DATA MD" button and 
use the VFO B knob to select Data A after selecting "Data A" with the Mode 
button.
Monty K2DLJ

On Dec 16, 2010, at 1:01 PM, Wes Stewart wrote:

> I don't do much PSK operation but I was just fiddling with it and noted 
> something puzzling (to me anyway).
> 
> Data mode A, although basically a USB mode, defaults to CW-like filtering.  
> The "NORM" setting is 400 Hz (my CW filter width, I guess), "Shift" is 1.5 
> KHz (and very limited) and "LO" and "HI" are locked out.  Considering how 
> much PSK operation is done, this is quite limiting.
> 
> Is there some compelling reason that I'm overlooking why the default for this 
> mode shouldn't be the same as SSB, with the options to have both SHIFT/WIDTH 
> and HI and LO CUT?
> 
> Wes  N7WS

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to