On Tuesday 04 August 2015 12:40:04 Gene Heskett wrote:

> On Tuesday 04 August 2015 11:59:17 andy pugh wrote:
> > On 4 August 2015 at 16:46, Gene Heskett <[email protected]> wrote:
> > > Is there a way to setp the 'A' so its homed forever, or to coax
> > > axis into displaying a separate button to home A wherever its at?
> >
> > If you give the A-axis a homing sequence number, then specify a
> > homing speed of zero then the A will get tagged as homed along with
> > the rest. Even if it isn't physically there.
> >
> > I have a part-time A axis on my mill, and do exactly that.
>
> Great Andy, thanks.
>
And it Just Works(TM).

Thanks Andy.

Cheers, Gene Heskett
-- 
"There are four boxes to be used in defense of liberty:
 soap, ballot, jury, and ammo. Please use in that order."
-Ed Howdershelt (Author)
Genes Web page <http://geneslinuxbox.net:6309/gene>

------------------------------------------------------------------------------