If this is commercial equipment, then the Class A limits would be appropriate.  
Class A equipment is that which is not marketed to the general public for use 
in the home.  This does not sound like something you would go to Best Buy to 
purchase.  And, Verification is the appropriate approval method for Class A 
products.

 

Ghery S. Pettit, NCE

Pettit EMC Consulting LLC

[email protected]

 

From: Michael Loerzer [mailto:[email protected]] 
Sent: Sunday, November 27, 2016 2:45 AM
To: [email protected]
Subject: [PSES] US EMC req. for EN 61010-1/EN 61326-1 equipment

 

Hi,

is for a modular 19'' draw-out unit system with a power supply and control unit 
to control LED modules for industrial application in the laboratory environment 
(EU: EN 61010-1, EN 61326-1 for LVD and EMCD) the FCC requirements mandatory?

In my point of view the answer is “yes”.

And I have recommended my customer to apply the FCC Part 15 method 
“verification”. Is that totally wrong?

Michael Loerzer

Globalnorm GmbH

 

 

 

-
----------------------------------------------------------------

This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at: 
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.

Website: http://www.ieee-pses.org/
Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe) 
<http://www.ieee-pses.org/list.html> 
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]> 

For policy questions, send mail to:
Jim Bacher <[email protected]>
David Heald <[email protected]> 


-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>

Reply via email to