Ok, so I don't use the "standard/typical" address?
0: 0x3bc 1: 0x378 2: 0x278 ?
So I would want to use lp1 for my lath and lp2 for my mill. From
what I understand I need to create two profiles, which is fine
I see stuff in Paxton-Patterson_Lathe.hal like
net xdir => parport.0.pin-02-out
net xstep => parport.0.pin-03-out
net ydir => parport.0.pin-04-out
net ystep => parport.0.pin-05-out
net zdir => parport.0.pin-06-out
net zstep => parport.0.pin-07-out
net adir => parport.0.pin-08-out
net astep => parport.0.pin-09-out
I kinda have the impression, it should be partport.1 for the next
parallel port and port.2 for the last one?
thanks,
Ron
On 12/19/19 10:57 PM, Phillip Carter wrote:
In the Base Information page you can select the number of parallel ports
Then in the Parallel Port 1 page you can select the parallel port using the
numbers 0,1 or 2 in the Parport BaseAddress entry
Then in the Parallel Port 2 page you can select the parallel port using the
numbers 0,1 or 2 in the entry that has no label in the bottom centre
On 20 Dec 2019, at 4:45 pm, R C <cjv...@gmail.com> wrote:
Hello,
when I run stepconf, it creates a *.hal file.
It seems that the parallel port used in there by default is "parport0" (I
have 3 parallel ports, 0, 1 and 2).
can I create a config for a specific port? or di I manually need to edit them?
(I would like to have one machine on lp1/partport1 and the other on
lp2/partport2 and not use parport0)
thanks,
Ron
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users