On 11 Jun 2013 at 16:13, 85VWCabrioletEV wrote:

>  I was told a fully charged US-125 is about 6.3v > 6.3x20=126v...but I
> just called American Battery in Hayward and they say > 6.6-6.8v per
> cell. 

Here's the word from the guy who should know.  Nawaz Qureshi, Vice President 
of Engineering, US Battery Mfg Co, says 100% SOC is typically >= 6.3 volts.

http://www.evdl.org/pages/socvolts.html

But resting voltage is still an unreliable way to measure SOC.  With flooded 
lead, a hydrometer is the way to do it.

David Roden - Akron, Ohio, USA
EVDL Administrator

= = = = = = = = = = = = = = = = = = = = = = = = = = = = =
EVDL Information: http://www.evdl.org/help/
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = 
Note: mail sent to "evpost" and "etpost" addresses will not 
reach me.  To send a private message, please obtain my 
email address from the webpage http://www.evdl.org/help/ .
= = = = = = = = = = = = = = = = = = = = = = = = = = = = =


_______________________________________________
UNSUBSCRIBE: http://www.evdl.org/help/index.html#usub
http://lists.evdl.org/listinfo.cgi/ev-evdl.org
For EV drag racing discussion, please use NEDRA 
(http://groups.yahoo.com/group/NEDRA)