First run 'no module blabla' and then power-off/on the lc. Met vriendelijke groet, Best regards,
Michiel Muhlenbaumer Atrato IP Networks (sent from mobile device) On 9 nov. 2010, at 16:58, Remco Bressers <[email protected]> wrote: > Hi, > > The other day, i inserted a brand new NI-XMR-10Gx4 in an XMR-4, but it > won't work correctly. > If i do a "show module", i see the following output on the slot : > > S2: NI-XMR-10Gx4 4-port 10GbE Module CARD_STATE_INTERACTIVE 20 > 0012.f2f5.d128 > (S2: Configured as NI-XMR-1Gx20-SFP 20-port 1GbE/100FX Module) > > What is the correct procedure to configure S2 as ni-xmr-10gx4 ? > > I tried : > > tel...@r(config)#module 2 ni-xmr-4-port-10g > Error: Please remove module from slot 2 first > tel...@r(config)# > > Is this the only (and correct) way? > > -- > Kind regards, > Signet bv > > Remco Bressers > _______________________________________________ > foundry-nsp mailing list > [email protected] > http://puck.nether.net/mailman/listinfo/foundry-nsp _______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp