FYI I have done a few service calls lately (mostly on 100/110 & 120) for extremely loud power supply fans. It seems the filter will get clogged and the plotters will coat the fan with a grimmy ink haze. it'll cause the fan to slow, then bearings get loud and if you keep going it'll throw a code. HP sells just power supply as one unit, but it looks like fan is just simple 65mm fan John
_____ From: [email protected] [mailto:[EMAIL PROTECTED] On Behalf Of kandoro Sent: Tuesday, August 12, 2008 2:34 PM To: [email protected] Subject: [HPDesignJet_Printers] Re: Keeping DesignJet 130 plugged in? --- In HPDesignJet_ <mailto:HPDesignJet_Printers%40yahoogroups.com> [EMAIL PROTECTED], "toasterboy66" <[EMAIL PROTECTED]> wrote: > > > > > Keeping the printer plugged in keeps the heater on at the > > > printhead > > > docking station. > > What? There is no heater anywhere on a DNJ130, and, for that matter, > PH should be kept cool, not hot. > > The DNJ130 has no automated PH maintenance whatsoever, if you > disconnect it or leave it plugged in makes no difference. > Hello: OK, there is no heater so the heat must be coming from a power supply/transformer, but there is SOME difference...I still wonder why that power supply or whatever it is remains ON after the power button is pushed off...Why not turn off everything if it makes no difference?...I also noticed that area gets cooler when the printer is just left totally on...This leads me to believe a fan must be blowing on that power supply when in operation... Again, I don't know and am probably making it much more complicated than it is...Still an interesting discussion... kd