As we've merged companies, our catalog environment has become very mixed. 
We have catalogs on both SMS & Non-SMS volumes.  Of the catalogs on the 
SMS volumes, some are in a systems dataset SMS pool and some are in 
standard production pools with lots of VSAM dataset - even VSAM clusters 
that belong to those catalogs. 

The catalogs in the standard production SMS pools also have a standard 
management class which has auto-backup enabled.  Backups occur daily.

We've never had a backup related issue, but I've never recovered a catalog 
from these backups either.  Per the redbook "ICF Catalog Backup & Recovery 
- A Practical Guide", HSM is listed as under the "Backup Utilities" 
section.  I quote:
"If the catalog resides on a SMS volume, the mangement class is used to 
control the backup frequency & the # of backup copies retained.  This 
allows you to define different management classes to achieve your needs 
for the backup frequency, and the # of backups you want to retain for 
different catalogs.  SMS invokes DFSMShsm, which in turn uses IDCAMS 
EXPORT to perform the backup.  Aliases are included in the backup copy."
- any mis-spellings are my own.

>From the zOS1.7 "Managing Catalogs" manual:
Although a catalog contains entries for SMS-managed data, the catalog 
itself does not have to be SMS-managed, but it is recommended that 
catalogs containing entries for SMS-managed data also be SMS-managed


As to the problem Kees listed below, I seem to remember something about 
this from the early days of ICF catalogs, but haven't seen anything more 
recent.  I did a quick check through a couple of the manuals & didn't find 
anything on this as a restriction, but to be honest I don't have the time 
available today to do a full blown search.
ddk


//////////////////////////////////////////////////

>>There used to be (warnings of) problems when mixing ICF catalogs and
>>VSAM dataset on the same volumes. 
>>IIRC there was a possibility of a deadly embrace when clusters from one
>>ICF catalog existed on the volume of the other ICF catalog and clusters
>>of the second ICF catalog existed on the volume of the first ICF
>>catalog.
**************************************************************************************
This e-mail message and all attachments transmitted with it may contain legally 
privileged and/or confidential information intended solely for the use of the 
addressee(s). If the reader of this message is not the intended recipient, you 
are hereby notified that any reading, dissemination, distribution, copying, 
forwarding or other use of this message or its attachments is strictly 
prohibited. If you have received this message in error, please notify the 
sender immediately and delete this message and all copies and backups thereof.

Thank you.
**************************************************************************************

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to