Dear All,

I just notice an error message : XCFAS    *IXC267E PROCESSING WITHOUT AN
ALTERNATE at my console. It means only one LOGR couple dataset is in Use.

But when I type : /D XCF,COUPLE,TYPE=LOGR I can see both of the Couple
Datasets(Primary and Alternate).

-D XCF,COUPLE,TYPE=LOGR
 IXC358I  08.16.46  DISPLAY XCF 453
 LOGR COUPLE DATA SETS
 PRIMARY    DSN: SYS1.LOGR.CDS04
            VOLSER: DT3SS1     DEVN: E374
            FORMAT TOD         MAXSYSTEM
            05/27/2011 14:36:08        8
            ADDITIONAL INFORMATION:
             LOGR COUPLE DATA SET FORMAT LEVEL: HBB6603
              LSR(100) LSTRR(10) DSEXTENT(50)
              SMDUPLEX(0)
 ALTERNATE  DSN: SYS1.LOGR.CDS05
            VOLSER: DT3SS1     DEVN: E374
            FORMAT TOD         MAXSYSTEM
            05/27/2011 14:36:09        8
            ADDITIONAL INFORMATION:
             LOGR COUPLE DATA SET FORMAT LEVEL: HBB6603
              LSR(100) LSTRR(10) DSEXTENT(50)
              SMDUPLEX(0)
 LOGR IN USE BY ALL SYSTEMS


Is it just an HeaLth Checker Message which was issued when there was only
Primary LOGR in place and Alternate was not defined ?

Could anyone please be kind enough to clarify ?

Jake

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN