Hi, I do have defined some spare CDSs to react to this message during IPL. There was no I/O error message for this Device anywhere but I presume the PSWITCH command would have made Alternate Dataset unavailable ? Now the Display Command shows both of the CDS are in place but why does this message still remaining at the Service Request(SR panel) ?
Jake On Fri, Jul 13, 2012 at 9:29 AM, Barbara Nitz <[email protected]> wrote: > >I just notice an error message : XCFAS *IXC267E PROCESSING WITHOUT AN > >ALTERNATE at my console. It means only one LOGR couple dataset is in Use. > .... > >Is it just an HeaLth Checker Message which was issued when there was only > >Primary LOGR in place and Alternate was not defined ? > > From the way you worded this I am assuming that you were in the process of > defining the LOGR CDSs? This is definitely NOT a health checker message. > > If you were not in the process of defining both CDSs, do you have > automation in place that reacts to that message? Were there I/O errors (any > kind) for that device since that message that might have caused the > alternate dataset to be temporarily unavailable? > > Barbara Nitz > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN