DUMP COMM=(SMF DUMP) the to the wtor XX,JOBNAME=SMF
Lizette -----Original Message----- >From: saurabh khandelwal <[email protected]> >Sent: Sep 13, 2012 12:29 PM >To: [email protected] >Subject: Re: SMF Dataset CLOSE PENDING ISSUE > >I just cheked in SMFPRM parmlib member, we are not collecting type 19 >record. > >I tried issueing contention command > > >D GRS,C >ISG343I 12.27.22 GRS STATUS 959 >NO ENQ RESOURCE CONTENTION EXISTS >NO REQUESTS PENDING FOR ISGLOCK STRUCTURE >NO LATCH CONTENTION EXISTS > >Can you please suggest, how to take console dump of SMF address space. > >Regards >Saurabh > >On Fri, Sep 14, 2012 at 12:53 AM, Lizette Koehler ><[email protected]>wrote: > >> From an old IBM Apar >> At times, a SWITCH command fails to occur within a large amount >> of time. This problem is usually seen when type19 records are >> being collected. This is due to the fact that SMF issues the >> LSPACE macro for every online device when information for >> SMFtype19 records is being gathered. LSPACE then causes an ENQ >> to be issued against each device. If an ENQ cannot be >> satisfied, LSPACE processing will wait. Depending on what the >> device is active for, the ENQ may take quite a while and the >> SWITCH (I) command cannot complete. >> >> >> Next, take a console dump of the SMF address space >> >> Then issue a D GRS,C command >> >> Let us know what you see. >> >> Lizette >> >> >> >> -----Original Message----- >> >From: saurabh khandelwal <[email protected]> >> >Sent: Sep 13, 2012 12:13 PM >> >To: [email protected] >> >Subject: Re: SMF Dataset CLOSE PENDING ISSUE >> > >> >I did the same, you suggested. But now D SMF command not showing me any >> >output. >> > >> >Not sure why. please suggest. >> > >> >Regards >> >Saurabh >> > >> >On Fri, Sep 14, 2012 at 12:31 AM, McKown, John < >> >[email protected]> wrote: >> > >> >> Is there some reason why you haven't created a MAN3; made a new >> SMFPRMnn, >> >> replacing MAN1 with a new MAN3; then doing the T SMF=nn command? Or have >> >> you tried and it failed? If it works, it should get rid of the CLOSE >> >> PENDING because the MAN1 entry will be gone and a new MAN3 entry >> appear. If >> >> that does happen, you can then dump MAN1. Once MAN1 has been dumped, you >> >> can do a T SMF=00 (or whatever the IPL value is for SMFPRMnn) to remove >> >> MAN3 and re-instate MAN1. Then dump MAN3 and delete it. >> >> >> >> -- >> >> John McKown >> >> Systems Engineer IV >> >> IT >> >> >> >> Administrative Services Group >> >> >> >> HealthMarkets(r) >> >> >> >> 9151 Boulevard 26 * N. Richland Hills * TX 76010 >> >> (817) 255-3225 phone * >> >> [email protected] * www.HealthMarkets.com >> >> >> >> Confidentiality Notice: This e-mail message may contain confidential or >> >> proprietary information. If you are not the intended recipient, please >> >> contact the sender by reply e-mail and destroy all copies of the >> original >> >> message. HealthMarkets(r) is the brand name for products underwritten >> and >> >> issued by the insurance subsidiaries of HealthMarkets, Inc. -The >> Chesapeake >> >> Life Insurance Company(r), Mid-West National Life Insurance Company of >> >> TennesseeSM and The MEGA Life and Health Insurance Company.SM >> >> >> >> >> >> > -----Original Message----- >> >> > From: IBM Mainframe Discussion List [mailto:[email protected]] >> >> > On Behalf Of saurabh khandelwal >> >> > Sent: Thursday, September 13, 2012 1:55 PM >> >> > To: [email protected] >> >> > Subject: Re: SMF Dataset CLOSE PENDING ISSUE >> >> > >> >> > I just dumped the MAN2 dataset. now D SMF shows MAN2 is active but 67 >> >> > % >> >> > full. >> >> > >> >> > Now D SMF showing me >> >> > >> >> > IEE974I 11.45.18 SMF DATA SETS 652 >> >> > NAME VOLSER SIZE(BLKS) %FULL STATUS >> >> > P-SYS1.GBU1.MAN1 PLXU05 10800 99 CLOSE PENDING >> >> > S-SYS1.GBU1.MAN2 PLXU05 10800 69 ACTIVE >> >> > >> >> > Can I use same >> >> > >> >> > >> >> > //SMFDMPM JOB 'SAURABH', >> >> > // NOTIFY=&SYSUID, >> >> > // CLASS=A, >> >> > // MSGCLASS=A >> >> > //STEP1 EXEC PGM=IFASMFDP,REGION=4M >> >> > //DUMPIN DD DSN=SYS1.GBU1.MAN2,DISP=SHR >> >> > //DUMPOUT DD DISP=(NEW,CATLG),DSN=arit.SMF.GBU1.D091312, >> >> > // UNIT=SYSALLDA,VOL=SER=STOR51,SPACE=(CYL,(30,10),RLSE), >> >> > // DCB=(RECFM=VBS,LRECL=32760,BLKSIZE=4096) >> >> > //SYSPRINT DD SYSOUT=* >> >> > //SYSIN DD * >> >> > INDD(DUMPIN,OPTIONS(ALL)) >> >> > >> >> > job for MAN1 dataset to take dump and clear it.. the way I did for >> >> > MAN2. >> >> > >> >> > please suggest. >> >> > >> >> > Regards >> >> > Saurabh >> >> > On Fri, Sep 14, 2012 at 12:11 AM, McKown, John < >> >> > [email protected]> wrote: >> >> > >> >> > > I haven't researched this, but is there a way to "restart" SMF? I >> >> > know >> >> > > some system address spaces can be FORCE'd and then started up again >> >> > using >> >> > > some procedure (which seems to be different depending on the system >> >> > address >> >> > > space). >> >> > > >> >> > > -- >> >> > > John McKown >> >> > > Systems Engineer IV >> >> > > IT >> >> > > >> >> > > Administrative Services Group >> >> > > >> >> > > HealthMarkets(r) >> >> > > >> >> > > 9151 Boulevard 26 * N. Richland Hills * TX 76010 >> >> > > (817) 255-3225 phone * >> >> > > [email protected] * www.HealthMarkets.com >> >> > > >> >> > > Confidentiality Notice: This e-mail message may contain confidential >> >> > or >> >> > > proprietary information. If you are not the intended recipient, >> >> > please >> >> > > contact the sender by reply e-mail and destroy all copies of the >> >> > original >> >> > > message. HealthMarkets(r) is the brand name for products >> underwritten >> >> > and >> >> > > issued by the insurance subsidiaries of HealthMarkets, Inc. -The >> >> > Chesapeake >> >> > > Life Insurance Company(r), Mid-West National Life Insurance Company >> >> > of >> >> > > TennesseeSM and The MEGA Life and Health Insurance Company.SM >> >> > > >> >> > > >> >> > > > -----Original Message----- >> >> > > > From: IBM Mainframe Discussion List [mailto:IBM- >> >> > [email protected]] >> >> > > > On Behalf Of Campbell Jay >> >> > > > Sent: Thursday, September 13, 2012 1:38 PM >> >> > > > To: [email protected] >> >> > > > Subject: Re: SMF Dataset CLOSE PENDING ISSUE >> >> > > > >> >> > > > >> >> > > > Take MAN1 out of SMFPRMxx when you put the new MAN3 in... Before T >> >> > > > SMF=xx. >> >> > > > Then do whatever you want with MAN1 while it's no longer allocated >> >> > to >> >> > > > SMF. >> >> > > > Then put it back after it's fix ( deleted - redefined ) >> >> > > > >> >> > > > Jay Campbell >> >> > > > IBM OS Support Section >> >> > > >> >> > > >> --------------------------------------------------------------------- >> >> > - >> >> > > For IBM-MAIN subscribe / signoff / archive access instructions, >> >> > > send email to [email protected] with the message: INFO IBM- >> >> > MAIN >> >> > > >> >> > >> >> > >> >> > >> >> > -- >> >> > Thanks & Regards >> >> > Saurabh Khandelwal >> >> > >> >> > ---------------------------------------------------------------------- >> >> > For IBM-MAIN subscribe / signoff / archive access instructions, >> >> > send email to [email protected] with the message: INFO >> IBM-MAIN >> >> >> >> ---------------------------------------------------------------------- >> >> For IBM-MAIN subscribe / signoff / archive access instructions, >> >> send email to [email protected] with the message: INFO IBM-MAIN >> >> >> > >> > >> > >> >-- >> >Thanks & Regards >> >Saurabh Khandelwal >> > >> >---------------------------------------------------------------------- >> >For IBM-MAIN subscribe / signoff / archive access instructions, >> >send email to [email protected] with the message: INFO IBM-MAIN >> >> ---------------------------------------------------------------------- >> For IBM-MAIN subscribe / signoff / archive access instructions, >> send email to [email protected] with the message: INFO IBM-MAIN >> > > > >-- >Thanks & Regards >Saurabh Khandelwal > >---------------------------------------------------------------------- >For IBM-MAIN subscribe / signoff / archive access instructions, >send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN