Hello John,
                      Thanks for reply. This will just start SMF, but what
about MAN1 dataset, which is in CLOSE pending state.
Rather then creating new SMFPRMnn member, can I create

1) MAN3 dataset and attache to the system dynamically to system and then
use I SMF command to switch MAN2 to MAN3.

But not sure, IF  this is right way to do it..

Regards
Saurabh

On Thu, Sep 13, 2012 at 11:44 PM, McKown, John <
[email protected]> wrote:

> Have you tried to dump MAN2? That might cause SMF to start using it. Can't
> hurt.
>
> Or, as I have done in the past, create a MAN3. Create a new SMFPRMnn and
> copy SMFPRM00 (or whatever) into it. Update the new SMFPRMnn to include the
> MAN3 dataset. Then issue T SMF=nn.
>
> --
> John McKown
> Systems Engineer IV
> IT
>
> Administrative Services Group
>
> HealthMarkets(r)
>
> 9151 Boulevard 26 * N. Richland Hills * TX 76010
> (817) 255-3225 phone *
> [email protected] * www.HealthMarkets.com
>
> Confidentiality Notice: This e-mail message may contain confidential or
> proprietary information. If you are not the intended recipient, please
> contact the sender by reply e-mail and destroy all copies of the original
> message. HealthMarkets(r) is the brand name for products underwritten and
> issued by the insurance subsidiaries of HealthMarkets, Inc. -The Chesapeake
> Life Insurance Company(r), Mid-West National Life Insurance Company of
> TennesseeSM and The MEGA Life and Health Insurance Company.SM
>
>
> > -----Original Message-----
> > From: IBM Mainframe Discussion List [mailto:[email protected]]
> > On Behalf Of saurabh khandelwal
> > Sent: Thursday, September 13, 2012 1:02 PM
> > To: [email protected]
> > Subject: SMF Dataset CLOSE PENDING ISSUE
> >
> > Hello Group,
> >                         We are in Sysplex  environment  and using Same
> > SMFPRM00 member and definition as below
> >
> > DSNAME(SYS1.&SYSNAME..MAN1
> >        SYS1.&SYSNAME..MAN2)
> >
> > and For one of system in Sysplex, D SMF command showing me
> >
> >
> >    NAME                VOLSER SIZE(BLKS) %FULL  STATUS
> >  P-SYS1.GBU1.MAN1     PLXU05     10800    99  CLOSE PENDING
> >  S-SYS1.GBU1.MAN2     PLXU05     10800     6  DUMP REQUIRED
> >
> > I tried to looking google for CLOSE PENDING status, that I need to
> > recreate
> > the this SMF MAN1 dataset, which is showing as CLOSE PENDING .
> >
> > But as MAN2 is also full and in DUMP REQUIRED state, I can not even
> > issue I
> > SMF command to switch over.
> >
> > Can you please help me handling this issue, so that SMF can start
> > working
> > in normal condition.
> > --
> > Thanks & Regards
> > Saurabh
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions,
> > send email to [email protected] with the message: INFO IBM-MAIN
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>



-- 
Thanks & Regards
Saurabh Khandelwal

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to