I did the same, you suggested. But now D SMF command not showing me any
output.

Not sure why. please suggest.

Regards
Saurabh

On Fri, Sep 14, 2012 at 12:31 AM, McKown, John <
[email protected]> wrote:

> Is there some reason why you haven't created a MAN3; made a new SMFPRMnn,
> replacing MAN1 with a new MAN3; then doing the T SMF=nn command? Or have
> you tried and it failed? If it works, it should get rid of the CLOSE
> PENDING because the MAN1 entry will be gone and a new MAN3 entry appear. If
> that does happen, you can then dump MAN1. Once MAN1 has been dumped, you
> can do a T SMF=00 (or whatever the IPL value is for SMFPRMnn) to remove
> MAN3 and re-instate MAN1. Then dump MAN3 and delete it.
>
> --
> John McKown
> Systems Engineer IV
> IT
>
> Administrative Services Group
>
> HealthMarkets(r)
>
> 9151 Boulevard 26 * N. Richland Hills * TX 76010
> (817) 255-3225 phone *
> [email protected] * www.HealthMarkets.com
>
> Confidentiality Notice: This e-mail message may contain confidential or
> proprietary information. If you are not the intended recipient, please
> contact the sender by reply e-mail and destroy all copies of the original
> message. HealthMarkets(r) is the brand name for products underwritten and
> issued by the insurance subsidiaries of HealthMarkets, Inc. -The Chesapeake
> Life Insurance Company(r), Mid-West National Life Insurance Company of
> TennesseeSM and The MEGA Life and Health Insurance Company.SM
>
>
> > -----Original Message-----
> > From: IBM Mainframe Discussion List [mailto:[email protected]]
> > On Behalf Of saurabh khandelwal
> > Sent: Thursday, September 13, 2012 1:55 PM
> > To: [email protected]
> > Subject: Re: SMF Dataset CLOSE PENDING ISSUE
> >
> > I just dumped the MAN2 dataset. now D SMF  shows MAN2 is active but 67
> > %
> > full.
> >
> > Now D SMF showing me
> >
> >  IEE974I 11.45.18 SMF DATA SETS 652
> >            NAME                VOLSER SIZE(BLKS) %FULL  STATUS
> >          P-SYS1.GBU1.MAN1     PLXU05     10800    99  CLOSE PENDING
> >          S-SYS1.GBU1.MAN2     PLXU05     10800    69  ACTIVE
> >
> > Can I use same
> >
> >
> > //SMFDMPM JOB 'SAURABH',
> > //         NOTIFY=&SYSUID,
> > //         CLASS=A,
> > //         MSGCLASS=A
> > //STEP1   EXEC PGM=IFASMFDP,REGION=4M
> > //DUMPIN   DD  DSN=SYS1.GBU1.MAN2,DISP=SHR
> > //DUMPOUT  DD  DISP=(NEW,CATLG),DSN=arit.SMF.GBU1.D091312,
> > //             UNIT=SYSALLDA,VOL=SER=STOR51,SPACE=(CYL,(30,10),RLSE),
> > //             DCB=(RECFM=VBS,LRECL=32760,BLKSIZE=4096)
> > //SYSPRINT DD  SYSOUT=*
> > //SYSIN    DD  *
> >      INDD(DUMPIN,OPTIONS(ALL))
> >
> > job for  MAN1 dataset to take dump and clear it.. the way I did for
> > MAN2.
> >
> > please suggest.
> >
> > Regards
> > Saurabh
> > On Fri, Sep 14, 2012 at 12:11 AM, McKown, John <
> > [email protected]> wrote:
> >
> > > I haven't researched this, but is there a way to "restart" SMF? I
> > know
> > > some system address spaces can be FORCE'd and then started up again
> > using
> > > some procedure (which seems to be different depending on the system
> > address
> > > space).
> > >
> > > --
> > > John McKown
> > > Systems Engineer IV
> > > IT
> > >
> > > Administrative Services Group
> > >
> > > HealthMarkets(r)
> > >
> > > 9151 Boulevard 26 * N. Richland Hills * TX 76010
> > > (817) 255-3225 phone *
> > > [email protected] * www.HealthMarkets.com
> > >
> > > Confidentiality Notice: This e-mail message may contain confidential
> > or
> > > proprietary information. If you are not the intended recipient,
> > please
> > > contact the sender by reply e-mail and destroy all copies of the
> > original
> > > message. HealthMarkets(r) is the brand name for products underwritten
> > and
> > > issued by the insurance subsidiaries of HealthMarkets, Inc. -The
> > Chesapeake
> > > Life Insurance Company(r), Mid-West National Life Insurance Company
> > of
> > > TennesseeSM and The MEGA Life and Health Insurance Company.SM
> > >
> > >
> > > > -----Original Message-----
> > > > From: IBM Mainframe Discussion List [mailto:IBM-
> > [email protected]]
> > > > On Behalf Of Campbell Jay
> > > > Sent: Thursday, September 13, 2012 1:38 PM
> > > > To: [email protected]
> > > > Subject: Re: SMF Dataset CLOSE PENDING ISSUE
> > > >
> > > >
> > > > Take MAN1 out of SMFPRMxx when you put the new MAN3 in... Before T
> > > > SMF=xx.
> > > > Then do whatever you want with MAN1 while it's no longer allocated
> > to
> > > > SMF.
> > > > Then put it back after it's fix ( deleted - redefined )
> > > >
> > > > Jay Campbell
> > > > IBM OS Support Section
> > >
> > > ---------------------------------------------------------------------
> > -
> > > For IBM-MAIN subscribe / signoff / archive access instructions,
> > > send email to [email protected] with the message: INFO IBM-
> > MAIN
> > >
> >
> >
> >
> > --
> > Thanks & Regards
> > Saurabh Khandelwal
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions,
> > send email to [email protected] with the message: INFO IBM-MAIN
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>



-- 
Thanks & Regards
Saurabh Khandelwal

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to