Yes, that's correct. The modules are loaded by CICS.

I read somewhere that SLIP scans CDE(Content Directory Entry
<https://www.ibm.com/docs/en/zos/2.3.0?topic=information-cde-heading>)
table for module information. Is it possible, CICS Load does not add entry
to CDE ? This is just my speculation though.


On Mon, Feb 21, 2022 at 4:20 PM Seymour J Metz <[email protected]> wrote:

> I would guess that you're debugging a module that CICS has loaded itself
> rather than loading via MVS contents supervision.
>
>
> --
> Shmuel (Seymour J.) Metz
> http://mason.gmu.edu/~smetz3
>
> ________________________________________
> From: IBM Mainframe Discussion List [[email protected]] on behalf
> of venkat rao bandaru [[email protected]]
> Sent: Monday, February 21, 2022 9:52 AM
> To: [email protected]
> Subject: Why SLIP PVTMOD/PVT EP does not work for Private load modules in
> CICS
>
> Greetings!
>
> Can you please share your experience around why SLIP IF/SA with PVTMOD/EP
> would not detect the load module in my CICS region ? Any SIT parameters in
> play ?
>
> SLIP IF/SA with PVTMOD/EP works for load modules in batch jobs.
>
> I have to use RANGE with absolute address to hit the SLIP, which is a
> concern for me. Please share if you have such experience and work arounds.
> Thank you in advance!
>
>
> --
> Best Regards
> *Venkat*
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>


-- 
Best Regards
*Venkat*

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to