Debugging?

-----Ursprungligt meddelande-----
Från: IBM Mainframe Discussion List <[email protected]> För Mike Schwab
Skickat: den 21 februari 2022 18:39
Till: [email protected]
Ämne: Re: Why SLIP PVTMOD/PVT EP does not work for Private load modules in CICS

CEMT is the CICS debugging command.

On Mon, Feb 21, 2022 at 4:15 PM venkat rao bandaru <[email protected]> wrote:
>
> Thank you for the information.
>
> On Mon, Feb 21, 2022 at 4:55 PM Seymour J Metz <[email protected]> wrote:
>
> > Yes, SLIP relies on MVS control blocks to locate modules. If there 
> > is no CDE or LPDE then SLIP has not way of locating the module by 
> > name. If you're licensed, you might ask the CICS support people at 
> > IBM how to trace in modules loaded by CICS.
> >
> >
> > --
> > Shmuel (Seymour J.) Metz
> > http://mason.gmu.edu/~smetz3
> >
> > ________________________________________
> > From: IBM Mainframe Discussion List [[email protected]] on 
> > behalf of venkat rao bandaru [[email protected]]
> > Sent: Monday, February 21, 2022 10:34 AM
> > To: [email protected]
> > Subject: Re: Why SLIP PVTMOD/PVT EP does not work for Private load 
> > modules in CICS
> >
> > Yes, that's correct. The modules are loaded by CICS.
> >
> > I read somewhere that SLIP scans CDE(Content Directory Entry
> > <https://www.ibm.com/docs/en/zos/2.3.0?topic=information-cde-heading
> > >) table for module information. Is it possible, CICS Load does not 
> > add entry to CDE ? This is just my speculation though.
> >
> >
> > On Mon, Feb 21, 2022 at 4:20 PM Seymour J Metz <[email protected]> wrote:
> >
> > > I would guess that you're debugging a module that CICS has loaded 
> > > itself rather than loading via MVS contents supervision.
> > >
> > >
> > > --
> > > Shmuel (Seymour J.) Metz
> > > http://mason.gmu.edu/~smetz3
> > >
> > > ________________________________________
> > > From: IBM Mainframe Discussion List [[email protected]] on 
> > > behalf of venkat rao bandaru [[email protected]]
> > > Sent: Monday, February 21, 2022 9:52 AM
> > > To: [email protected]
> > > Subject: Why SLIP PVTMOD/PVT EP does not work for Private load 
> > > modules in CICS
> > >
> > > Greetings!
> > >
> > > Can you please share your experience around why SLIP IF/SA with 
> > > PVTMOD/EP would not detect the load module in my CICS region ? Any 
> > > SIT parameters
> > in
> > > play ?
> > >
> > > SLIP IF/SA with PVTMOD/EP works for load modules in batch jobs.
> > >
> > > I have to use RANGE with absolute address to hit the SLIP, which 
> > > is a concern for me. Please share if you have such experience and 
> > > work
> > arounds.
> > > Thank you in advance!
> > >
> > >
> > > --
> > > Best Regards
> > > *Venkat*
> > >
> > > ------------------------------------------------------------------
> > > ---- For IBM-MAIN subscribe / signoff / archive access 
> > > instructions, send email to [email protected] with the 
> > > message: INFO IBM-MAIN
> > >
> > > ------------------------------------------------------------------
> > > ---- For IBM-MAIN subscribe / signoff / archive access 
> > > instructions, send email to [email protected] with the 
> > > message: INFO IBM-MAIN
> > >
> >
> >
> > --
> > Best Regards
> > *Venkat*
> >
> > --------------------------------------------------------------------
> > -- For IBM-MAIN subscribe / signoff / archive access instructions, 
> > send email to [email protected] with the message: INFO 
> > IBM-MAIN
> >
> > --------------------------------------------------------------------
> > -- For IBM-MAIN subscribe / signoff / archive access instructions, 
> > send email to [email protected] with the message: INFO 
> > IBM-MAIN
> >
>
>
> --
> Best Regards
> *Venkat*
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send 
> email to [email protected] with the message: INFO IBM-MAIN



--
Mike A Schwab, Springfield IL USA
Where do Forest Rangers go to get away from it all?

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to