Jim, I stand 'slightly' corrected. Module SS14RC02 isn't in a LNKLST library, it is in the LPA. Module SS14A32 is in the LNKLST and that's the module my job abended on in my second attempt.
I just got off the phone with SyncSort support and worked through the issue. While it doesn't explain why I would sometimes get the 306 and sometimes get a good run, I now know that I need to have my SyncSort library APF authorized to run in my environment. Rex -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Jim Mulder Sent: Friday, December 20, 2013 11:30 AM To: [email protected] Subject: Re: APF authorization and JOBLIB DD card > The way I'm reading your explanation below, if I have program ABCDE > that needs to run APF authorized, and it is sitting both in the > LNKLST and in an unauthorized JOBLIB/STEPLIB, the system will skip > loading the unauthorized module from STEPLIB and load the authorized > version from LNKLST? That is correct, and that's why I suggested that a dump may be useful. We would also like to see the results from the following commands: SETPROG LNKLST,TEST,NAME=CURRENT,MOD=SS14RC02 SETPROG LNKLST,TEST,NAME=CURRENT,MOD=SS14RC02 CSV503I MODULE SS14RC02 COULD NOT BE LOCATED USING LNKLST SET CURRENT SETPROG LNKLST,TEST,NAME=CURRENT,MOD=SS14A32 CSV502I MODULE SS14A32 WAS LOCATED 673 IN DATA SET SYS1.SFG1B.SYNCSORT.R14.SYNCLINK USING LNKLST SET CURRENT D PROG,LNK D PROG,LNK CSV470I 11.58.29 LNKLST DISPLAY 724 LNKLST SET LNKLST00 LNKAUTH=LNKLST ENTRY APF VOLUME DSNAME 1 A Z1BR9A SYS1.LINKLIB 2 A Z1BR9A SYS1.MIGLIB 3 A Z1BR9A SYS1.CSSLIB 4 A Z1BR9A SYS1.SIEALNKE 5 A Z1BR9A SYS1.SIEAMIGE 6 Z1BMSI SYS1.SFG1B.SYNCSORT.R14.SYNCLINK 7 A Z1BR9A CEE.SCEERUN2 8 A Z1BR9A CEE.SCEERUN 9 A Z1BCAT CPAC.LINKLIB 10 A Z1BCAT CPAC.VTAMLIB 11 Z1BR9A SYS1.SICELINK 12 A Z1BR9A TCPIP.SEZALOAD 13 A Z1BR9A CSF.SCSFMOD0 14 A Z1BR9A SCRIPT.R40.DCFLOAD 15 A Z1BR9A SYS1.SHASLNKE 16 Z1BR9A GIM.SGIMLMD0 17 A Z1BR9A SYS1.CMDLIB 18 A Z1BR9A SYS1.SIOALMOD 19 A Z1BR9A SYS1.SHASMIG 20 A Z1BR9A CBC.SCLBDLL 21 A Z1BR9A SYS1.SBDTLIB 22 A Z1BR9A ASM.SASMMOD1 23 Z1BR9A EOX.SEPHLOD1 24 A Z1BR9A CBC.SCLBDLL2 25 A Z1BR9A SYS1.DFQLLIB 26 A Z1BR9B IGY.SIGYCOMP 27 A Z1BR9A FFST.V120ESA.SEPWMOD2 28 A Z1BR9A SYS1.SBDTLINK 29 A Z1BR9A REXX.SEAGALT 30 A Z1BR9A SYS1.SBDTCMD 31 Z1BR9B IXM.SIXMLOD1 32 A Z1BR9A IOE.SIOELMOD 33 A Z1BR9A SYS1.SCUNIMG 34 Z1BR9A EUV.SEUVLINK 35 A Z1BR9A SYS1.NFSLIBE 36 Z1BR9A SYS1.SCBDHENU 37 Z1BR9A GDDM.SADMMOD 38 A Z1BR9A SYS1.DGTLLIB 39 Z1BR9A FFST.V120ESA.SEPWMOD4 40 A Z1BR9A ISP.SISPLOAD 41 Z1BR9A EOY.SEOYLOAD Jim Mulder z/OS System Test IBM Corp. Poughkeepsie, NY ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN The information contained in this message is confidential, protected from disclosure and may be legally privileged. If the reader of this message is not the intended recipient or an employee or agent responsible for delivering this message to the intended recipient, you are hereby notified that any disclosure, distribution, copying, or any action taken or action omitted in reliance on it, is strictly prohibited and may be unlawful. If you have received this communication in error, please notify us immediately by replying to this message and destroy the material in its entirety, whether in electronic or hard copy format. Thank you. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN