On Thu, May 5, 2016 at 2:07 PM, phil yogendran <[email protected]> wrote:

> Hello,
>
> We recently performed a DR exercise and on one of the LPAR's, the CSA was
> smaller by about 800k. Parmlib specification in DR and production were
> identical. The LPAR affected is our designated 'network' box so there are
> no apps or subsystems like CICS or IMS running on it.
>
> Any thoughts on what could make CSA shrink at IPL,  particularly when
> parmlib was not changed? The IODF in DR would have been different but I
> can't see that affecting CSA.
>

​CSA rounds to 1M boundries. A bigger IODF could be due to more devices,
which mean more UCBs, and so less CSA, assuming that the 1M​ boundry didn't
get bumped up to the next higher boundry. Just a possibility.



>
> Looking forward to your comments.
>
> Thanks,
>
> Phil
>


-- 
The unfacts, did we have them, are too imprecisely few to warrant our
certitude.

Maranatha! <><
John McKown

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN