I did think it was a bigger IODF but in my case SQA in DR has gone down
implying a smaller IODF. However, CSA has also gone down. Here's some
inform from DR and Prod;

DR:          SQA      988K                CSA     3.43M

Prod:       SQA     1.11M                CSA     4.28M



On Thu, May 5, 2016 at 3:25 PM, Bob Rutledge <[email protected]> wrote:

> On 5/5/2016 3:07 PM, phil yogendran wrote:
>
>> Hello,
>>
>> We recently performed a DR exercise and on one of the LPAR's, the CSA was
>> smaller by about 800k. Parmlib specification in DR and production were
>> identical. The LPAR affected is our designated 'network' box so there are
>> no apps or subsystems like CICS or IMS running on it.
>>
>> Any thoughts on what could make CSA shrink at IPL,  particularly when
>> parmlib was not changed? The IODF in DR would have been different but I
>> can't see that affecting CSA.
>>
>
> If your production CSA size is considerably larger than the specification
> in parmlib, the DR IODF could be scarfing more SQA which would affect the
> size of CSA.
>
> Bob
>
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to