On Thu, 6 Apr 2017 13:53:49 +0000, Herring, Bobby <[email protected]> wrote:
>I was the one that responded. Here are our definitions: > >Feature Value >OFFLINE Yes >DYNAMIC Yes >LOCANY Yes >LIBRARY No >AUTOSWITCH Yes >LIBRARY-ID 00001 >LIBPORT-ID 01 >MTL Yes >SHARABLE Yes >COMPACT Yes > >But, we do have compact set to yes. And our devices are defined as 3490. > >EMC had us break the definitions into eight groups of 16. Each has a different >LIBPORT. We have 1-4 and 11-14. Thanks. Maybe 3490 vs. 3590 would matter for SHARABLE causing a problem. Or not.. :-) Mark -- Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS ITIL v3 Foundation Certified mailto:[email protected] Mark's MVS Utilities: http://www.mzelden.com/mvsutil.html Systems Programming expert at http://search390.techtarget.com/ateExperts/ ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN