Dear Ray Sir, Thank you for your reply. I have still two queries. (1) In matpower 4.1, the size of hessian obtained from ACOPF is 66*66. But shouldn't it be 72*72, as it has 30 voltage magnitudes, 30 voltage angles, 6 active power flow injections and 6 reactive power flow injections. (total size=30+30+6+6=72)? (2) Is there any equation for determining the size of Jacobian for ACOPF?
Thank you ________________________________ From: Ray Zimmerman <[email protected]> To: MATPOWER discussion forum <[email protected]> Sent: Thursday, 1 August 2013 6:49 PM Subject: Re: Hessian See Table D-9 in the User's Manual. opf_hessfcn.m -- Ray Zimmerman Senior Research Associate B30 Warren Hall, Cornell University, Ithaca, NY 14853 phone: (607) 255-9645 On Aug 1, 2013, at 6:18 AM, Kartik Pandya <[email protected]> wrote: > > > > >________________________________ > >Dear Ray sir, >Which .m file calculates Hessian matrix in case of ACOPF? > > >Thank you