DEar Dr Ray Zimmerman,
 
In the ACOPF equations we have the line_coductance G and line susceptance B, 
where G = r/(r^2+X^2) and B= - x / (r^2+x^2)
where r and x are the series resistance and reactance (pu) respectively. Some 
other authors however, take B = x / (r^2 + x^2)
ie. without the minus symbol in the beginning. 
 
May I ask,  which one is used in the matpower code ?
 
 
 
 

________________________________
 From: Ray Zimmerman <[email protected]>
To: MATPOWER discussion forum <[email protected]> 
Sent: Thursday, August 1, 2013 2:19 PM
Subject: Re: Hessian
  


See Table D-9 in the User's Manual.
     opf_hessfcn.m



-- 
Ray Zimmerman
Senior Research Associate
B30 Warren Hall, Cornell University, Ithaca, NY 14853
phone: (607) 255-9645



 

On Aug 1, 2013, at 6:18 AM, Kartik Pandya <[email protected]> wrote:


>
>
> 
>
>________________________________
> 
>Dear Ray sir,
>Which .m file calculates Hessian matrix in case of ACOPF?
>
>
>Thank you   

Reply via email to