Am 30.06.2016 um 08:30 schrieb Colin Reese:
> 
> Thus, you need to know whether you are looking for a value interpreted 
> as a DS1825 or as a MAX31850. Because they are indistinguishable from 
> software,
>
They are distinguishable. The DS1825 configuration register bit 7 reads
always 0. The MAX31850 (and MAX31826) configuration register bit 7 reads
always 1. See the datasheets (pp. 8/13/9 resp.).


> 
> So ... should I just read the scratchpad and do my own conversion, or 
> can someone rewrite this?
> 
We can and should. Unfortunately I have none of these devices at hand.


Kind regards

        Jan

------------------------------------------------------------------------------
Attend Shape: An AT&T Tech Expo July 15-16. Meet us at AT&T Park in San
Francisco, CA to explore cutting-edge tech and listen to tech luminaries
present their vision of the future. This family event has something for
everyone, including kids. Get more information and register today.
http://sdm.link/attshape
_______________________________________________
Owfs-developers mailing list
Owfs-developers@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/owfs-developers

Reply via email to