Am 30.06.2016 um 08:30 schrieb Colin Reese: > > Thus, you need to know whether you are looking for a value interpreted > as a DS1825 or as a MAX31850. Because they are indistinguishable from > software, > They are distinguishable. The DS1825 configuration register bit 7 reads always 0. The MAX31850 (and MAX31826) configuration register bit 7 reads always 1. See the datasheets (pp. 8/13/9 resp.).
> > So ... should I just read the scratchpad and do my own conversion, or > can someone rewrite this? > We can and should. Unfortunately I have none of these devices at hand. Kind regards Jan ------------------------------------------------------------------------------ Attend Shape: An AT&T Tech Expo July 15-16. Meet us at AT&T Park in San Francisco, CA to explore cutting-edge tech and listen to tech luminaries present their vision of the future. This family event has something for everyone, including kids. Get more information and register today. http://sdm.link/attshape _______________________________________________ Owfs-developers mailing list Owfs-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/owfs-developers