On 09.09.2016 15:50, Uwe Bonnes wrote:
>  So you mean that */temperature* should return the thermocouple temperature
>  and */thermocouple should vanish and */coldjunction (or a similar name)
>  should appear and  return the internal temperature?
>
> This sounds also much clearer to me and I will try to make a patch to the
> docs and the code, if I get confirmation that this approch is right.
For what it's worth, I can confirm that this makes sense.
> Any other ideas for a sensible filename to return internal temperature?
I'd use "reference_temperature" or some suitable abbreviation thereof.
Don't forget that this is not always the *cold* junction, you can use a
thermocouple to measure how cold your liquid nitrogen or CO2 is …

-- 
-- Matthias Urlichs


------------------------------------------------------------------------------