Steve -

Thanks for the tips - I for one will start to play with it.  Any pointers as
to the options ?  I'm using 99SE right now, and choosing (it's only a
2-layer board)

* IPC-D-356A
* Top Layer
* Bottom Layer
* Board outline -> mechanical layer with the board outline
* Conductor Traces

I don't have the Adjacency Information box checked ...

-- 
Dean Carpenter
deano at areyes com
94TT :)
----- Original Message ----- 
From: "Steve Fenton" <[EMAIL PROTECTED]>
To: <[email protected]>
Sent: Wednesday, March 23, 2005 12:56 PM
Subject: [PEDA] Re: HELP!! Gerber Output Contains Random Subtle Errors
WithPlane Connects!


> Matt (and everybody!),
>
> There's really no need to eyeball gerbers to check connectivity. A much
> quicker and better (semi-)automated gerber check can be done as follows:-
>
> 1. Generate gerbers as normal.
> 2. Generate an IPC-D-356 netlist from the PCB layout tool. This is
generated
> from the PCB file itself (*not* from the gerbers) and, in rough terms,
> contains a textual description of the gerbers. IPC netlist can be
generated
> in DXP SP2 from CAM generation, Insert TestPoint Report (you might have to
> check a few boxes first time round.) Do not generate the IPC netlist from
> within Camtastic!
> 3. Open a new blank Camtastic document.
> 4. Import the copper layer gerbers and drill files into Camtastic. No need
> to bother with paste, resist, silkscreen etc.
> 5. Within Camtastic, generate a netlist from the gerber files.
> 6. Within Camtastic, compare the netlist with the IPC netlist file (the
one
> you exported from the PCB in step 2).
>
> Steps 4-6 are covered in the help files under something like
> 'Importing/checking Gerbers'. I'm not actually at the machine with DXP
> installed, so I can't be any more detailed, but it's only been a couple of
> weeks since the last time I did this.
>
> The PCB vs gerber netlist check will likely give you warnings about
> unconnected pads (fixing holes and so on), but should otherwise match. If
> not, the gerbers do match the PCB file. Simple as that.
>
> As an extra safety check, I always send the IPC netlist with the gerbers
to
> the fab house and ask them to compare their gerber-generated netlist with
> the supplied IPC netlist - before they start etching! At worst case you'll
> lose a day of their pre-processing time. But at least you won't waste
> days/weeks making and assembling a batch of useless boards.
>
> I can't emphasise this point enough: the IPC netlist is generated from the
> PCB design and *not* from the gerbers. As long as you remember that, its
> purpose becomes obvious.
>
> Sorry this won't help you this time round, but it's saved my bacon several
> times over the years. I got burned long ago with stitching vias which
> connected Power and Ground layers together, and looked around for the
> solution. Well, I asked the fab guys...
>
> I can't really believe more people don't supply their fab house with IPC
> netlist along with gerbers. My fab house tells me I'm their only customer
> who does. I guess everybody else ends up with more respins than I do!
>
> Sorry for my late reply.
>
> Cheers,
> Steve
>
>
>
> Matt Polak wrote:
>
> >
> >         Hey Gang,
> >
> >         We've come across a *major* show-stopper problem on some
> > boards we just got back from our board house. For whatever reason,
> > there are a few spots where DXP decided that our vias should just not
> > randomly connect to the power planes their nets are assigned to. Most
> > of the board is fine, but we've already found one major cluster that's
> > problematic. Take a look at this...
> >
> >         http://www.raven-systems.com/temp/missing_connections.gif
> >
> >         As you can clearly see, when viewing the power plane
> > connections in the layout editor, the interconnects show fine. When
> > viewing the verbatim generated Gerbers, however (RIGHT IN DXP!) there
> > are missing plane connections! The entire top set of 7 vias are not
> > connected to ANY planes, whilst the bottom row are connected just fine
> > where appropriate. I looked at the properties of all of the top-row
> > vias, and they're just fine - nothing out of the ordinary.
> > Surprisingly most of the other vias on the board (including the bottom
> > row) connect just fine!!
> >
> >         Has anyone seen this, or know of a way to have DXP scan for
> > it, or fix it? We just lost a lot of time and money on this
> > spin-and-assemble due to this export problem, and I have a feeling
> > we'll likely be finding more of these little via issues as we continue
> > to bring the board up. And worse yet, we have to do another Gerber
> > generation - am I going to have to hand-check several thousand vias on
> > the Gerber outputs to ensure this doesn't happen again?
> >
> >         Honestly, this is bringing me to an absolute last straw in
> > continuing to use Protel if we can't even be guaranteed consistent
> > WYSIWYG output. Someone PLEASE tell me we did something wrong? I'm
> > starting to lose patience with Altium's little "features" in the
> > software.
> >
> > Frustrated as hell,
> > -- Matt
>
>
> ____________________________________________________________
> You are subscribed to the PEDA discussion forum
>
> To Post messages:
> mailto:[email protected]
>
> Unsubscribe and Other Options:
> http://techservinc.com/mailman/listinfo/peda_techservinc.com
>
> Browse or Search Old Archives (2001-2004):
> http://www.mail-archive.com/[email protected]
>
> Browse or Search Current Archives (2004-Current):
> http://www.mail-archive.com/[email protected]
>
>

 
____________________________________________________________
You are subscribed to the PEDA discussion forum

To Post messages:
mailto:[email protected]

Unsubscribe and Other Options:
http://techservinc.com/mailman/listinfo/peda_techservinc.com

Browse or Search Old Archives (2001-2004):
http://www.mail-archive.com/[email protected]
 
Browse or Search Current Archives (2004-Current):
http://www.mail-archive.com/[email protected]

Reply via email to