Hi Linda,

I think your referring to exit analytical whole body counting as opposed to 
exit passive whole body counting because both are considered whole body 
counting for internal activity.

At Surry, normal RCA and RA (aka Protected Area) passive whole body counting 
satisfies the requirement for both exit and annual whole body counts.

Yes, we have special documentation for passive whole body counting.  In 
accordance with ANI Engineering Inspection Criteria Section 8.5, Revision 5, an 
internal sensitivity study was conducted for each make and model of Personnel 
Contamination Monitor (PCM) / Personal Monitor (PM) used at the station to take 
credit for passive whole body counting.

John M. Sukosky, CHP
Health Physicist III
Radiological Protection, Surry Power Station

Dominion Generation
Phone: 757-365-2594; Internal: 8-798-2594
Fax: 757-365-2668
Pager: 804-273-3030 3636; E-mail: 
[email protected]<mailto:[email protected]>

From: Sewell, Linda [mailto:[email protected]]
Sent: Tuesday, November 24, 2015 1:37 PM
To: [email protected]
Subject: [powernet] Whole Body Counting Benchmark

Hi All,

I don't see a recent benchmark on this subject.

Does your site perform exit whole body counting?
If no, do you have any special documentation for passive monitoring or just 
take credit for the normal RCA egress process?

For Diablo Canyon we currently do perform exit whole body counting.

Thanks and Happy Thanksgiving,

Linda

Linda M. Sewell, CHP
Principal Health Physicist
Pacific Gas & Electric Company
Diablo Canyon Power Plant
MS 119/1/117
PO Box 56
Avila Beach, CA 93424
                                                                                
                                                                
P: 805.545.4315 | F: 805.545.2618| [email protected]<mailto:[email protected]>




CONFIDENTIALITY NOTICE:  This electronic message contains information which may 
be legally confidential and or privileged and does not in any case represent a 
firm ENERGY COMMODITY bid or offer relating thereto which binds the sender 
without an additional express written confirmation to that effect.  The 
information is intended solely for the individual or entity named above and 
access by anyone else is unauthorized.  If you are not the intended recipient, 
any disclosure, copying, distribution, or use of the contents of this 
information is prohibited and may be unlawful.  If you have received this 
electronic transmission in error, please reply immediately to the sender that 
you have received the message in error, and delete it.  Thank you.

Reply via email to