Browns Ferry is the same as SQN except we have the PM-7 Monitors in addition to 
the GEM-5.  We performed a sensitive study on both monitors

Glad to see Powernet back.

From: Rolph, James Thomas Jr [mailto:[email protected]]
Sent: Tuesday, November 24, 2015 2:59 PM
To: Sewell, Linda; [email protected]
Subject: [powernet] RE: Whole Body Counting Benchmark


TVA External Message. Please use caution when opening.
Linda,
At TVA- Sequoyah we perform entrance passive monitoring using a log. Our GEM-5s 
are able to see approximately 0.55% of an ALI using our radionuclide mix, based 
on the sensitivity study we have performed. Individuals who enter an RCA pass 
through 2 GEM-5s before leaving our site, at the RCA exit, and at the PA exit.  
We take credit for passive monitoring, and only perform whole body count if an 
individual alarms a GEM-5, or has known intake incident.

Jim Rolph, CHP
RP Technical Support Superintendent
(423) 843-8115- Office
(423) 593-0247- Cell

From: Sewell, Linda [mailto:[email protected]]
Sent: Tuesday, November 24, 2015 1:37 PM
To: [email protected]<mailto:[email protected]>
Subject: [powernet] Whole Body Counting Benchmark


TVA External Message. Please use caution when opening.
Hi All,

I don't see a recent benchmark on this subject.

Does your site perform exit whole body counting?
If no, do you have any special documentation for passive monitoring or just 
take credit for the normal RCA egress process?

For Diablo Canyon we currently do perform exit whole body counting.

Thanks and Happy Thanksgiving,

Linda

Linda M. Sewell, CHP
Principal Health Physicist
Pacific Gas & Electric Company
Diablo Canyon Power Plant
MS 119/1/117
PO Box 56
Avila Beach, CA 93424
                                                                                
                                                                
P: 805.545.4315 | F: 805.545.2618| [email protected]<mailto:[email protected]>