Monticello performs a WBC, if at all possible, for all terminations for workers that have entered the RCA. We also have a documented sensitivity study IAW ANI criteria for our portal monitors for those we cannot do a WBC. This is a timely benchmark in that my management wishes to perform WBCs only for investigative purposes and rely on passive monitoring for routine exits/terminations. Happy Thanksgiving
Scott Huneycutt Senior Health Physicist Monticello Nuclear Generating Plant Sent from Scott's iPhone On Nov 24, 2015, at 12:37 PM, "Sewell, Linda" <[email protected]<mailto:[email protected]>> wrote: Hi All, I don't see a recent benchmark on this subject. Does your site perform exit whole body counting? If no, do you have any special documentation for passive monitoring or just take credit for the normal RCA egress process? For Diablo Canyon we currently do perform exit whole body counting. Thanks and Happy Thanksgiving, Linda Linda M. Sewell, CHP Principal Health Physicist Pacific Gas & Electric Company Diablo Canyon Power Plant MS 119/1/117 PO Box 56 Avila Beach, CA 93424 P: 805.545.4315 | F: 805.545.2618| [email protected]<mailto:[email protected]> Powernet - a service of the Health Physics Society Power Reactor Section Reply to: [email protected] To unsubscribe: send message to [email protected] archive(Nov15->): http://www.mail-archive.com/[email protected]/ (Pending) archive(<October 2015): http://www.mail-archive.com/[email protected]/ If questions, contact E. Scott Medling, CHP at [email protected]
