Monticello performs a WBC, if at all possible, for all terminations for workers 
that have entered the RCA.
We also have a documented sensitivity study IAW ANI criteria for our portal 
monitors for those we cannot do a WBC.
This is a timely benchmark in that my management wishes to perform WBCs only 
for investigative purposes and rely on passive monitoring for routine 
exits/terminations.
Happy Thanksgiving

Scott Huneycutt
Senior Health Physicist
Monticello Nuclear Generating Plant
Sent from Scott's iPhone

On Nov 24, 2015, at 12:37 PM, "Sewell, Linda" 
<[email protected]<mailto:[email protected]>> wrote:

Hi All,

I don't see a recent benchmark on this subject.

Does your site perform exit whole body counting?
If no, do you have any special documentation for passive monitoring or just 
take credit for the normal RCA egress process?

For Diablo Canyon we currently do perform exit whole body counting.

Thanks and Happy Thanksgiving,

Linda

Linda M. Sewell, CHP
Principal Health Physicist
Pacific Gas & Electric Company
Diablo Canyon Power Plant
MS 119/1/117
PO Box 56
Avila Beach, CA 93424
                                                                                
                                                                
P: 805.545.4315 | F: 805.545.2618| [email protected]<mailto:[email protected]>