DataAvailable fires with as few as one characters. You need to put them
into a buffer and watch for the EOL. This tends to be characteristic of
serial ports. It's not yet clear too me whether or not this is also
characteristic of USB-Serial converter systems as I have not tried it
yet.
Jim
On Apr 23, 2006, at 8:59 AM, Emile Schwarz wrote:
Hi,
REALbasic 2005r4 Pro
Mac OS X 10.4.6 on PowerBook G4 15" Alu (8-2004)
brand new project,
add a serial control in the window
put in the Window.Open:
add a ListBox (call it LBModem, set it to 5 Columns - same results
with 3 columns earlier)
LBModem.AddRow ""
serial1.Write "ATI0" + EndOfLine.Windows
in Serial1.DataAvailable put:
LBModem.Cell(LBModem.LastIndex,2) = Me.ReadAll(Encodings.UTF8) // *
Run and you get wrong entries in the Cells; sometimes all info goes on
one Cell (ATI0960OK), sometimes all ifos goes to the correct cells
(ATI0,960,OK).
Any idea ?
Emile
PS: why DataAvailable is fired so many times after a single call ?
* Same results without encodings