Re: [PSES] Compliance engineering contacts at Plextor and Netgear

2012-02-24 Thread Edward Fitzgerald
Dear All, Contact made to the relevant compliance people in Netgear and Plextor. Thanks for all your suggestions of where to look! Have a great weekend! Edward Quoting Mark Gandler markgand...@hotmail.com: Netgear: here here. Please take me off the February 21st most wanted list. Ed,

[PSES] Compliance engineering contacts at Plextor and Netgear

2012-02-21 Thread Edward Fitzgerald
in to a larger system that is about to go through UL Safety testing. Many thanks for your support, Edward Fitzgerald cell: +447768533100 skype: edward_fitzgerald - This message is from the IEEE Product Safety Engineering Society

Re: Russian regulations

2003-07-31 Thread Edward Fitzgerald
), so if you'd like to send me more details of what you're proposing during that time I will look into the matter further during the week of 11-August and get back to you. Kind regards, Edward Edward Fitzgerald Director, European Technology Services http://ets-tele.com/ M: +44 7768 5

Thai and Korean EMC/EMI and Safety standards

2000-10-24 Thread Edward Fitzgerald
. I have yet to confirm the timescales for each of the above, if anyone has more detailed information I'd be glad to hear from you. Best regards, Edward Fitzgerald Director Direct Tel. : +44 1202 20 09 22 Mobile Tel. : +44 7768 53 31 00 European Technology Services (EMEA) Specialist Global

RE: ETSI standards vs NEBS

2000-10-06 Thread Edward Fitzgerald
To: Edward Fitzgerald Subject: Re: ETSI standards vs NEBS -Original Message- From: Edward Fitzgerald edward.fitzger...@ets-tele.com To: 'Gorodetsky, Vitaly' vgorodet...@canoga.com; 'Dave Wilson' dwil...@alidian.com; 'n...@world.std.com' n...@world.std.com; 'emc-p...@ieee.org' emc-p...@ieee.org

RE: ETSI standards vs NEBS

2000-09-29 Thread Edward Fitzgerald
to the State Committee. In terms of test reports demonstrating compliance with Safety and EMC, NEBS reports would not be accepted albeit that they are now closely aligned with International standards. Best regards, Edward Fitzgerald Director Direct Tel. : +44 1202 20 09 22 Mobile Tel. : +44 7768 53 31

RE: Just Curious; VOIP Network

2000-08-08 Thread Edward Fitzgerald
recommend you start by browsing the TIPHON public area of the ETSI web site for a more in depth (free) analysis. Best regards, Edward Edward Fitzgerald Director Direct Tel. : +44 1202 20 09 22 Mobile Tel. : +44 7768 53 31 00 European Technology Services (EMEA) Specialist Global Compliance

RE: EMF Radiation : Test labs

2000-07-14 Thread Edward Fitzgerald
recommendations on suitable laboratories.   Waiting in anticipation for a flood of emails!  Edward -Original Message- From: Edward Fitzgerald Sent: Tuesday, July 04, 2000 4:56 PM To: EMC-PSTC (E-mail) Subject: EMF Radiation : Test labs Hi,   I am currently putting together a list

EMF Radiation : Test labs

2000-07-04 Thread Edward Fitzgerald
the recommendation be on price, service level or just a high level of competence.   Many thanks, Edward Fitzgerald Director Direct Tel. : +44 1202 20 09 22 Mobile Tel. : +44 7768 53 31 00 European Technology Services (EMEA) Specialist Global Compliance and Regulatory Consultancy Regional Offices

RE: APLAC

2000-04-05 Thread Edward Fitzgerald
regards, Edward Fitzgerald Director, ETS -Original Message- From: raymond...@dixonsasia.com.hk [mailto:raymond...@dixonsasia.com.hk] Sent: Wednesday, April 05, 2000 7:09 AM To: emc-p...@ieee.org Subject: APLAC I recently heard that China National Accreditation of Laboratories (CNACL

RE: Cell Phone Hazard - follow up

2000-04-05 Thread Edward Fitzgerald
, and satellite mobile phone handsets that operate in the radiofrequency range 800 MHz to 2.5 GHz. ETSI is currently working on the issue of EMF radiation, but they are a long way from agreeing a definitive set of requirements and test suites. Best regards, Edward Fitzgerald Director Direct Tel. : +44 1202

RE: Russian Certification of Products

2000-03-16 Thread Edward Fitzgerald
of the overall costs. I've produced an explanatory overview for our clients, let me know if you'd like a copy. Best regards, Edward Edward Fitzgerald Director Direct Tel. : +44 1202 20 09 22 GSM Tel. : +44 7768 53 31 00 European Technology Services (EMEA) Specialist Global Compliance and Regulatory

RE: EN55024 EN50082

1999-12-14 Thread Edward Fitzgerald
Peter, In brief, EN 50 082 is the generic standard and EN 50 024 is a product standard that takes precedence over the generic standard. I hope this helps a little, let me know if you need a more in depth answer. Edward Fitzgerald Director Direct Tel. : +44 1202 20 09 22 GSM Tel. : +44 4685 33

RE: UL and CE Mark Acceptance

1999-11-20 Thread Edward Fitzgerald
. A Manufacturer's DofC for Safety must be generated and must state the Hungarian national standards equivalent to the CENELEC EN's (e.g. MSZ EN 60 950-92 = EN 60 950) Best regards, Edward Edward Fitzgerald Director Direct Tel. : +44 1202 20 09 22 GSM Tel. : +44 4685 33 100 European Technology Services

RE: internet information (worldwide electricity supplies)

1999-11-18 Thread Edward Fitzgerald
Dear Laura et al. I wasn't sure if it was yourself or someone else that had asked about worldwide electricity supply voltages and frequencies. Anyway a brief list can be viewed at the following link : http://www.ets-tele.com/tics/global/volt_freq.htm Best regards, Edward Fitzgerald Director

RE: Immunity Requirements for Australia

1999-10-27 Thread Edward Fitzgerald
should you wish to confirm the above: http://www.ets-tele.com/tics/global/au/index.htm Best regards, Edward Fitzgerald Director GSM Tel. : +44 4685 33 100 European Technology Services (Australia) Pty. Ltd. Specialist Global Compliance and Regulatory Consultancy Regional Offices in Australia, Canada

RE: CE Countries

1999-10-09 Thread Edward Fitzgerald
the official translation) this will include the CE marking regulation as part of the manufacturers' self declaration. A landmark in Hungarian certification as the EMC procedures previously were cause for many delays in product launch. Best regards, Edward Fitzgerald Director Direct Tel. : +44 1202 20 09 22

RE: IEC 60990 Vs IEC 60950

1999-09-29 Thread Edward Fitzgerald
manufacturers implementing the standard). An Informative Reference however is generally to a standard where either no mandatory requirements have been imposed or that it is not within the public domain at that time. Edward Fitzgerald Director Direct Tel. : +44 1202 20 09 22 GSM Tel. : +44 4685 33

RE: 21 rack for Europe

1999-07-02 Thread Edward Fitzgerald
on EN 300 119-x). From previous experience you'll have to come up with a rack mounting kit arrangement which will cover each of the various rack standards - EIA, NEBS and ETSI if you're building a system for use everywhere. I hope this helps. Best regards, Edward Edward Fitzgerald International

RE: Australian Electrical Approvals Authority

1999-06-28 Thread Edward Fitzgerald
5031 Australia Let me know if you need further details or in-country assistance. Best regards, Edward Fitzgerald Director Direct Tel. : +44 1202 20 09 22 GSM Tel. : +44 4685 33 100 European Technology Services (Australia) Pty. Ltd. Specialist Global Compliance Consultancy Offices in Australia

RE: Worldwide ITE Requirements

1999-05-11 Thread Edward Fitzgerald
regards, Edward Edward Fitzgerald International Approvals Consultant Direct Tel. : +44 1202 20 09 22 GSM Tel. : +44 4685 33 100 European Technology Services Specialist Global Compliance Consultancy Offices in Australia, Canada and the UK. http://www.ets-tele.com -Original Message- From

Virus Alert - Do Not open email attachments with happy99.exe or l ist.doc from anyone

1999-03-29 Thread Edward Fitzgerald
for more links on how to remove thses viruses.   Edward Fitzgerald International Approvals Consultant Direct Tel. : +44 1202 20 09 22 GSM Tel. : +44 4685 33 100 European Technology Services Specialist Global Compliance Consultancy Offices in Australia, Canada and the UK http://www.ets-tele.com

RE: Saudi Arabia

1999-03-08 Thread Edward Fitzgerald
sites and can find nothing relating to Saudi - perhaps you should take a look yourself at [http://www.sgsgroup.com] as their search facility wasn't working when I tried a moment ago. Sorry I can't be more specific. Best regards, Edward Edward Fitzgerald International Approvals Consultant Direct

RE: EMC Requirements for the Czech Republic

1999-03-07 Thread Edward Fitzgerald
the old Federal requirements applicable to Telecom. Hope this clarifies your question, Edward Edward Fitzgerald International Approvals Consultant Direct Tel. : +44 1202 20 09 22 GSM Tel. : +44 4685 33 100 European Technology Services Specialist Global Compliance Consultancy Offices in the UK

RE: C Tick..

1999-03-01 Thread Edward Fitzgerald
an email off-line if you need further guidance on the standards or compliance areas you will need to consider.   Best regards, Edward Fitzgerald   Director, European Technology Services Specialist Communications Compliance Consultancy With offices in the UK, Australia and Canada asia-pac.off