Wow - I haven't heard Teradata in a number of years. Check to make sure your
device addresses are still listed in IECIOSxx of SYS1.PARMLIB
MIH DEV=(-),TIME=nn:nn
Ken
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Prashant Joshi3
Sent: Thursday, January
Joseph,
I know for a fact that there are job classes that are available for long
running jobs. Have you tried to use those?
You'll want to read up on Syncsort from Precisely as we are not licensed for
DFSORT from IBM.
Ken Mazer
IRS Systems Programmer 25 years
-Original Message-
From:
Make sure you have an odd number of twists in between the two CEC's. Each
jumper cable counts as one twist. If you're connected via dark fiber then make
sure that has a twist in the path. If you can't change the ends of the dark
fiber you might be able to separate one end of an LC jumper
Bob,
Are any of the PF Keys 13-24 working? It sounds like maybe the keyboard map in
Attachmate isn't allowing the shift-key to work. I always use the "IBM
3191.ekm or "IBM 3191.xkb" keyboard maps in my InfoConnect/Attachmate session.
Ken
-Original Message-
From: IBM Mainframe
The old Share Sing Along book had an orange cover, I have one in the office but
since I've been working from home since March I can't put my hands on it right
away.
Ken Mazer
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Dave Jones
Sent: Monday, June 08, 2020
Here's a site that may have more info for your reading pleasure,
http://www.punchcardreader.com/
I have used this service to decode several hundred punched cards several years
ago.
The historical society that I'm a member of has thousands of punched cards with
no real way to read them anymore.
Jerry,
We have 5 CECs in one IODF. Are you using HCD or HMC? Either way it's
possible to combine the three IODFs into one, I would probably do one at a time.
#1) From the processor list you can COPY from the current IODF to a new
target IODF.
#2) Your SNA Network name needs to match
Mark,
You've indicated that you have 8 systems in a sysplex does that mean 8 CEC or 8
z/OS systems?
How many CEC's do you have?
Are you doing POR for each CEC?
In the RESET profile you point to the IOCDS slot that you'll POR from. In
SYS1.IPLPARM(LOADxx) you should specify "**" in columns 10 &
Don,
Is your Visara connected via OSA-ICC? Does the console in question receive the
OSA-ICC three line display?
You didn't indicate the reason for running Standalone DFDSS, did you get a new
processor or are you setting up a new DR environment.
The reason I ask these questions is that we just
Skip,
I remember this being a pain to setup and test initially. But we did finally
get it to work.
Directions below are basic and you're already past some of these steps, but I'm
including them if others want to follow along.
Using an ID with SYSPROG permissions:
Single Click on "HMC
Yes, there are jobs in the tapetool utilities (COPYRFSH) that will allow one to
sync clusters within a grid, there's a whitepaper on techdocs that explains the
process.
We've been working this process for about a month now. We went from a two way
grid with a third stand alone VE to a four way
When setting up a HyperSwap target subsystem in HCD does anyone know if the
same CHPIDs have to be used or can you use different CHPIDs?
We have a subsystem with 20480 Mod-54 devices that we need to be able to
HyperSwap to a new subsystem.
I'm unable to use the same CHPIDs for both due to
Sometime ago it was suggest that we have a XCF ARM Policy so that our
automation product automatically restart if it went down.
We've never setup an ARM policy and I'm looking for a sample, other than the
one in SAMPLIB. Anyone have a simple one they would be willing to share?
Thanks,
Ken
While configuring CKD storage on a new IBM DS8880 I discovered that the default
number of cylinders for a 3390-27 and a 3390-54 has changed.
Caution should be taken when your defining new storage.
I've always assumed that a 3390-27 had 32,760 cylinders. Not the case anymore,
if using the GUI
Anyone ever receive emails from IBM about z Systems machine information that
you're not registered to receive?
For example this morning I received notification for a 2096 with a serial
number that we've never owned or leased.
The machine 2096-X is back level on MCL activation. There are 49
Crispin,
Required, no. Preferred, Yes.
It's always better to spread the IO over as many IO-Bays and FICON cards as
possible.
Ken Mazer
This Cranky Systems Programmer says “Let's be careful out there”
Proper, Prior, Planning, Prevents, Piss, Poor, Performance
"Education is what remains
Lionel,
How about the IBM Logrec Viewer V1.1 see
http://www-03.ibm.com/systems/z/os/zos/tools/downloads/logrec-viewer.html
Ken Mazer
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@listserv.ua.edu] On Behalf
Of Dyck, Lionel B. (TRA)
Sent: Friday, January 06,
Sorry for the formatting of the first message. I forgot HMTL not supported and
the excel table got out of whack. Hopefully this will work out better.
We're in the process of configuring two new IBM DS8886 for EAV volumes and I
have a few questions for the storage experts
Keeping in mind that
We're in the process of configuring two new IBM DS8886 for EAV volumes and I
have a few questions for the storage experts
Keeping in mind that each LCU on the DS8Ks only support 256 unit addresses.
Our current methodology is to configure each LCU on the DS8Ks with 128 base
devices and 32 alias
Lionel,
I wrote an assembler macro several years ago.
Needless to say I haven't updated it since 1994.
May not be complete but it's a place to start.
MACRO
DEVICES
***
*