These started popping up on my console after I changed the
system names of my modedems. Any idea what I should do?
Thanks,
John Kicklighter
Internet 2xtreme
DBD::Sybase::db do failed: Server message number=170 severity=15 state=1 line=1
server=ESPRESSO text=Line 1: Incorrect syntax near ','.
Hi John,
Youll need to send a trace outoput at level 4 so we can see what the SQL
statement its trying to do is.
Cheers.
On Feb 16, 1:34pm, Internet 2xtreme wrote:
> Subject: (RADIATOR) SessSQL errors
> These started popping up on my console after I changed the
> system names of my modedem
This looks like what is popping up when I login/out from one of our NASes. This
one is a 3com HiPerARC.
into RADONLINE (USERNAME, NASIDENTIFIER, NASPORT, ACCTSESSIONID, TIME_STAMP,
FRAMEDIPADDRESS, NASPORTTYPE,
SERVICETYPE) values ('root', '209.63.215.10', , '!root7657', 919201557, '', 'Virtua
I'm getting ready to activate some PM3s. I don't have any of these
currently in the network. The dictionary I use now is for the
3com/USRobotics. Are there any attributes that I will need to transfer
from the "dictionary.livingston" to create a hibrid dictionary that will
work? If not, I'l
The detail file is being created, and SOMETIMES I get a Modem-Start
accounting record dropped. I don't however get true start or stop
records. When using the radpwtst program, I DO get start/stop records
generated.
The acct_port1 and acct_host1 are set correctly. The secret is correct
as shown by
Dear Friends,
I am new on this list and still hesitate to buy a Radiator radius. I work
for big ISP. I would like to know something from users' point of view.
Is this software stable and easy configurable for medium qualified system
administrator? Is it open enough in growing ISP environment?
Hi,
I've downloaded the 2.13beta which is supposed to be able to auth off an NT
box whilst running on Linux. Firstly, let me say that it installed so
easily on RH5.2. We have previously been using N, and it has not crashed
once. (Radiator that is...NT crashes often) :)
Anyway, Radiator is ru
On Wed, 17 Feb 1999, Andrzej Blaszczyk wrote:
> I am new on this list and still hesitate to buy a Radiator radius. I work
> for big ISP. I would like to know something from users' point of view.
You can always ask for an evaluation version and test it for yourself. We
did and are very satisfie
You can now disregard this. Nortel swooped in this AM, and have
updated the software on the Annex. Full accounting detail is now
being squirted into Radiator.
--
Stephen Ollis <[EMAIL PROTECTED]> Ph: +61 2 9911 1606(BH)
Team Leader, Server Systems - Network Engineering +61 2 9911 1555(FAX)