[wsjt-devel] IC-7300 control lost

2017-03-03 Thread Pino Zollo
End of show . El 02/03/17 a las 19:11, wsjt-devel-requ...@lists.sourceforge.net escribió: > #4 You still haven't sent us enough of the log to see what was going on > what it stopped... rig_register (372) icom_init: civ_version=1 rig_set_conf: civaddr='0x94' rig:rig_open called s

Re: [wsjt-devel] IC-7300 control lost

2017-03-02 Thread Bill Somerville
Hi Pino, On 02/03/2017 22:33, Pino Zollo wrote: write_block(): TX 7 bytes fe fe 94 e0 1c 00 fd... <-- Wrong command read_string(): RX 7 characters fe fe 94 e0 1c 00 fd... <-- wrong command echoed read_string

[wsjt-devel] IC-7300 control lost

2017-03-02 Thread Pino Zollo
El 02/03/17 a las 19:11, wsjt-devel-requ...@lists.sourceforge.net escribió: > > I'm no expert, but is this command legit? > > > fe fe 94 e0 1c 00 fd > > > According to the manual > http://www.icom.co.jp/world/support/download/manual/pdf/IC-7300_ENG_CD_0.pdf > and this site http://w

Re: [wsjt-devel] IC-7300 control lost

2017-03-02 Thread Bill Somerville
On 02/03/2017 20:37, David Tiller wrote: I'm no expert, but is this command legit? fe fe 94 e0 1c 00 fd Hi David, yes it is. Many Icom CAT commands come in set and query versions, the difference is that the query version leaves off the value. So 1c 00 is the query command, and in t

Re: [wsjt-devel] IC-7300 control lost

2017-03-02 Thread David Tiller
aptech/> Best Firms 2016 #2 in Information Technology ____ From: Pino Zollo Sent: Thursday, March 2, 2017 2:22 PM To: wsjt-devel@lists.sourceforge.net Subject: [wsjt-devel] IC-7300 control lost El 02/03/17 a las 15:26, wsjt-devel-requ...@lists.sourceforge.net e

Re: [wsjt-devel] IC-7300 control lost

2017-03-02 Thread Bill Somerville
On 02/03/2017 19:42, Pino Zollo wrote: > rigctl(d): t 'currVFO' '' '' '' > write_block(): TX 7 bytes > fe fe 94 e0 1c 00 fd... > read_string(): RX 7 characters > fe fe 94 e0 1c 00 fd... > read_string(): RX 8 cha

[wsjt-devel] IC-7300 control lost

2017-03-02 Thread Pino Zollo
El 02/03/17 a las 16:36, wsjt-devel-requ...@lists.sourceforge.net escribió: > #4 You still haven't sent us enough of the log to see what was going on > what it stopped... > > I will do it tonight --- write_block(): TX 7 bytes fe fe 94 e0 1a 03 fd.

[wsjt-devel] IC-7300 control lost

2017-03-02 Thread Pino Zollo
El 02/03/17 a las 15:26, wsjt-devel-requ...@lists.sourceforge.net escribió: > #4 You still haven't sent us enough of the log to see what was going on > what it stopped... > > I will do it tonight > >> I suspect a computer problem on your part right now. > maybethe behavior is the same on th

[wsjt-devel] IC-7300 control lost

2017-03-02 Thread Pino Zollo
El 02/03/17 a las 11:21, wsjt-devel-requ...@lists.sourceforge.net escribió: > #1 Try reducing the poll interval on WSJT-X in File/Settings/Radio in the > upper right corner. Tried polling from 1 to 2 secondsno change. #2 What OS are you on? Linux Mint 17.3 #3 Have you tried uninstalling

Re: [wsjt-devel] IC-7300 control lost

2017-03-02 Thread Black Michael
oblem on your part right now. de Mike W9MDB  From: Pino Zollo To: wsjt-devel@lists.sourceforge.net Sent: Thursday, March 2, 2017 6:33 AM Subject: [wsjt-devel] IC-7300 control lost El 02/03/17 a las 05:28, wsjt-devel-requ...@lists.sourceforge.net escribió: > Do you have a dummy

[wsjt-devel] IC-7300 control lost

2017-03-02 Thread Pino Zollo
El 02/03/17 a las 05:28, wsjt-devel-requ...@lists.sourceforge.net escribió: > Do you have a dummy load you can test with?One question is does it fail only > when you transmit and on certain bands? > de Mike W9MDB Hi Mike The problem shows also in RX only... Any how I did wound the USB cable

Re: [wsjt-devel] IC-7300 control lost

2017-03-01 Thread Black Michael
Do you have a dummy load you can test with?One question is does it fail only when you transmit and on certain bands? de Mike W9MDB From: Pino Zollo To: wsjt-devel@lists.sourceforge.net Sent: Wednesday, March 1, 2017 3:12 PM Subject: [wsjt-devel] IC-7300 control lost El 01/03/17

Re: [wsjt-devel] IC-7300 control lost

2017-03-01 Thread Bill Somerville
On 01/03/2017 21:12, Pino Zollo wrote: > 000fe fe e0 94 1c 00 00 fd > rigctl(d): f 'currVFO' '' '' '' > write_block():339 failed -1 - Input/output error > write_block():339 failed -1 - Input/output error > write_block():339 failed -1 - Input/output error > w

[wsjt-devel] IC-7300 control lost

2017-03-01 Thread Pino Zollo
El 01/03/17 a las 15:15, wsjt-devel-requ...@lists.sourceforge.net escribió: >> HI Pino, >> >> do you have the correct baud rate selected and the correct serial port. >> -s and -r arguments to rigctld. >> > > ohoops.. this is the right command: > > /usr/local/bin/rigctld-wsjtx -m 373 -c 0x94 -s

[wsjt-devel] IC-7300 control lost

2017-03-01 Thread Pino Zollo
El 01/03/17 a las 12:27, wsjt-devel-requ...@lists.sourceforge.net escribió: > HI Pino, > > do you have the correct baud rate selected and the correct serial port. > -s and -r arguments to rigctld. > ohoops.. this is the right command: /usr/local/bin/rigctld-wsjtx -m 373 -c 0x94 -s 9600 -r

Re: [wsjt-devel] IC-7300 control lost

2017-03-01 Thread Bill Somerville
On 01/03/2017 12:59, Pino Zollo wrote: > it goes in timeout straight. > > --- > icom_init: civ_version=1 > rig_set_conf: civaddr='0x94' > rig:rig_open called > Opened rig model 373, 'IC-7300' > Backend version: 0.7.2, Status: Stable > Connection opened from localhost:49024 > rigctl(d):

[wsjt-devel] IC-7300 control lost

2017-03-01 Thread Pino Zollo
El 01/03/17 a las 01:25, wsjt-devel-requ...@lists.sourceforge.net escribió: > In the WSJT-X rig selection you use "Hamlib NET rigctl".? > First, start rigctld-wstx like you did before. ?When you select the rig as > above you'll see it connect and messages start flowing.That's the capture I > ne

Re: [wsjt-devel] IC-7300 control lost

2017-02-28 Thread Black Michael
t can get quite long. de Mike W9MDB From: Pino Zollo To: wsjt-devel@lists.sourceforge.net Sent: Tuesday, February 28, 2017 6:57 PM Subject: [wsjt-devel] IC-7300 control lost El 28/02/17 a las 21:49, wsjt-devel-requ...@lists.sourceforge.net escribió: > You need to run WSJT-X us

[wsjt-devel] IC-7300 control lost

2017-02-28 Thread Pino Zollo
El 28/02/17 a las 21:49, wsjt-devel-requ...@lists.sourceforge.net escribió: > You need to run WSJT-X using Hamlib NET rigctl and re-run this until it fails. > de Mike W9MDB Hi Mike, it is not clear to me please which commands shall I give ? 73 Pino ZP4KFX