Hi Bob,

>Just to clarify myself, A 1xx response is not required to have a To tag. A
>To tag is required to establish a dialog. A 1xx without a tag is still
>outside of a dialog.

My understanding of chapter 8.2.7 in bis-05 is that a 1xx (non-100, that
is) provisional response MUST contain a To tag.

This was discussed on the SIP mailing list a long time ago. If I
remember correctly the use of the To tag in provisional responses was
then added to the bis as a SHOULD, but has then became mandatory.

Regards,

Christer Holmberg
Ericsson Finland