Hi Nigel,

Based on RFC3270 (http://www.rfc-editor.org/rfc/rfc3720.txt) the ExpCmdSN field 
is the "next Expected Command Sequence Number".  Since that should be the 
status sequence number plus 1, I would assume the Solaris iSCSI target is 
misbehaving.  The initial command sent to the Solaris iSCSI target was a "1", 
so the expected next command sequence should be "2", not "1".

Eric
 
 
This message posted from opensolaris.org
_______________________________________________
storage-discuss mailing list
[email protected]
http://mail.opensolaris.org/mailman/listinfo/storage-discuss