In message <[EMAIL PROTECTED]>, Bruce Griffiths writes:
>Poul-Henning Kamp wrote:


>The point is that actually using latches in this way is considered poor
>design practice when crossing clock domains.

The latches do NOT span clock domains, they are in the same domain
as the counter.

The signals that make captures the counter value in the latch is
synchronized to the global clock using 3 D flip-flops.

-- 
Poul-Henning Kamp       | UNIX since Zilog Zeus 3.20
[EMAIL PROTECTED]         | TCP/IP since RFC 956
FreeBSD committer       | BSD since 4.3-tahoe    
Never attribute to malice what can adequately be explained by incompetence.