Bruce,

We recently tested a cellular phone by setting it on a  ground plane and
zapping it with the ESD gun. Obviously, the cellular phone kept working
when it was set down; perhaps your product does not?

roger
[email protected]

======================== previous thread =================================
>Hello Everyone!
>
>Has anyone out there had any experience with handheld products being tested for
>ESD immunity?  We have a product for testing that can only be operated while
>being held by the operator and its only used for a few seconds at a time.  IEC
>801-2/IEC 1000-4-2 does not seem to address this situation.  Is ESD testing
>required?  I can't see how the product would be hit be ESD as its only operated
>while being held in someones hand.
>
>Any reply would be appreciated.
>
>Bruce Fagley
>TUV Rheinland
>[email protected]
>
>

Reply via email to