I use 2 other sensors
one is tfa wind and the other is acurite lightning sensor
I don't use the wind sensor of the wh3080
my skin inside the current.inc the right strings of UV and radiation but
the result is UV N / A and radiation N / A
Il giorno martedì 16 agosto 2022 alle 17:46:27 UTC+2 Peppe ha scritto:
> good evening,
> I will try first of all to put order and to answer your questions:
> the weather station is a froggit wh3080 with separate sensors at 433 mhz,
> therefore the old model. Here is the photo in jpg
>
> [image: Profi-radio-Stazione-Meteo-wh3080-luce-UV-USB.jpg]
> IThis is the result of what the stick sees thanks to the rtl command:
> sudo rtl_433 -R 32
>
> time : 2022-08-16 17:20:15
> model : Fineoffset-WHx080 Msg type : 0
> Station ID: 226
> Battery : 1 Temperature: 32.9 C Humidity : 36 %
> Wind Direction: 0 Wind avg speed: 0.00 Wind gust : 0.00
> Total rainfall: 65.1 Integrity : CRC
> _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
> _ _ _
> time : 2022-08-16 17:20:27
> model : Fineoffset-WHx080 Msg type : 2
> UV Sensor ID: 225 Sensor Status: OK UV Index : 4
> Lux : 84102.8 Watts/m : 123.14 Integrity : CRC
> _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
> _ _ _
> time : 2022-08-16 17:20:27
> model : Fineoffset-WHx080 Msg type : 2
> UV Sensor ID: 225 Sensor Status: OK UV Index : 4
> Lux : 84102.8 Watts/m : 123.14 Integrity : CRC
> _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
> _ _ _
> time : 2022-08-16 17:20:27
> model : Fineoffset-WHx080 Msg type : 2
> UV Sensor ID: 225 Sensor Status: OK UV Index : 4
> Lux : 84102.8 Watts/m : 123.14 Integrity : CRC
>
> the command lines inserted in the sdr:
> driver = user.sdr
> cmd = rtl_433 -R 32 -R 40 -R 42
> the command lines inserted in the sensor map
> UV = uv_index.225.FOWH3080Packet
> radiation = radiation.225.FOWH3080Packet
> also replaced by another entry
> UV = uv_index.225.FOWHx080Packet
> radiation = radiation.225.FOWHx3080Packet
>
> finally this is the result of the driver weewx sdr using the command
> PYTHONPATH=/home/weewx/bin python /home/weewx/bin/user/sdr.py --config
> /home/weewx/weewx.conf --hide=parsed,mapped
>
> out: ['{"time" : "2022-08-16 15:40:27", "model" : "Fineoffset-WHx080",
> "subtype" : 2, "uv_sensor_id" : 225, "uv_status" : "OK", "uv_index" : 3,
> "lux" : 66370.100, "wm" : 97.174, "mic" : "CRC"}\n', '{"time" : "2022-08-16
> 15:40:27", "model" : "Fineoffset-WHx080", "subtype" : 2, "uv_sensor_id" :
> 225, "uv_status" : "OK", "uv_index" : 3, "lux" : 66370.100, "wm" : 97.174,
> "mic" : "CRC"}\n', '{"time" : "2022-08-16 15:40:27", "model" :
> "Fineoffset-WHx080", "subtype" : 2, "uv_sensor_id" : 225, "uv_status" :
> "OK", "uv_index" : 3, "lux" : 66370.100, "wm" : 97.174, "mic" : "CRC"}\n']
>
>
> inside the syslog there is no trace of UV or radiation
>
>
>> I currently don't have it in front of me and am just writing from my
>> phone, but maybe i can give a few hints:
>>
>> Which sdr command do you use in your config file? Try adding:
>>
>> -Y classic
>>
>> Which WHx080 model do you have? Is it the old one with separated sensors
>> or the newer all in one sensor array?
>>
>> Do the other sensors work with your sdr weewx conf?
>>
>> Please keep in mind, the whx080 never really gave accurate solar
>> radiation readings in the first place, mine showed 600 instead of 900 w/m2
>> last month. The newer wh65 array does this a lot better imo (but worse for
>> wind gusts instead..)
>>
>> You will have to add in stdCalibrate -> Corrections
>>
>> radiation = radiation/126.7
>>
>> To convert the lux illuminance to w/m2 radiation readings.
>>
>> There is a way to show the recorded loop packets in the terminal but i
>> can't remember the command, if you find it, check and see if weewx is
>> getting the data. If so, make sure the uv and radiation fields exist in
>> your database, and whether or not they are listed in your skin.conf (for
>> plots as well as the current values)
>>
>>
>>
>> [email protected] schrieb am Sonntag, 14. August 2022 um 14:14:29 UTC+2:
>>
>>> can anyone help me?
>>>
>>> Il giorno martedì 9 agosto 2022 alle 16:49:48 UTC+2 Peppe ha scritto:
>>>
>>>> sorry, the last line is wrong
>>>> this is what I wanted to write
>>>> radiation = radiation.225.FOWH3080Packet
>>>>
>>>> Il giorno mar 9 ago 2022 alle ore 16:46 Peppe <[email protected]> ha
>>>> scritto:
>>>>
>>>>> good evening
>>>>> I put the two lines on the sensor map but it doesn't work. I am
>>>>> writing you a series of attempts made by me along with your suggestions:
>>>>> UV = uv_index.225.FOWHx080Packet
>>>>> radiation = light.225.FOWHx080Packet
>>>>> radiation = radiation.225.FOWHx080Packet
>>>>> UV = uv_index.225.FOWH3080Packet
>>>>> radiation = light.225.FOWH3080Packet
>>>>> radiation = light.225.FOWH3080Packet
>>>>> I don't know what I did wrong.
>>>>> I rewrite the data I receive from my Nesdr:
>>>>> {"time": "2022-08-09 14:42:36", "model": "Fineoffset-WHx080",
>>>>> "subtype": 2, "uv_sensor_id": 225, "uv_status": "OK", "uv_index ": 3,"
>>>>> lux
>>>>> ": 36888.800," wm ": 54.010," mic ":" CRC "}
>>>>>
>>>>> Il giorno lun 8 ago 2022 alle ore 16:44 Peppe <[email protected]> ha
>>>>> scritto:
>>>>>
>>>>>>
>>>>>> first of all thank you so much for answering me. I was wrong in
>>>>>> transcribing the syslog.
>>>>>> this is correct: {"time": "2022-08-07 13:26:39", "model":
>>>>>> "Fineoffset-WHx080", "subtype": 2, "uv_sensor_id": 225, "uv_status": "
>>>>>> OK
>>>>>> "," uv_index ": 2," lux ": 32082.000," wm ": 46,972," mic ":" CRC "}
>>>>>> I'll try your suggestions and post them here
>>>>>>
>>>>>> Il giorno lunedì 8 agosto 2022 alle 09:18:08 UTC+2 [email protected]
>>>>>> ha scritto:
>>>>>>
>>>>>>> I've never seen "*End*offset-WHx080", not sure if this is available
>>>>>>> in sdr.py, but maybe I'm wrong.
>>>>>>>
>>>>>>> Mine works with following sensor map entries:
>>>>>>>
>>>>>>> UV = uv_index.*.FOWHx080Packet
>>>>>>> radiation = light.*.FOWHx080Packet
>>>>>>>
>>>>>>> You can replace *** with your ID (necessary if there are other
>>>>>>> WHx080 stations around)
>>>>>>>
>>>>>>>
>>>>>>> [email protected] schrieb am Sonntag, 7. August 2022 um 15:45:17
>>>>>>> UTC+2:
>>>>>>>
>>>>>>>> I used a weeewx 4.8.0 installation using the weewx-sdr driver
>>>>>>>> updated on February 12th of this year and capturing the sensors at 433
>>>>>>>> mhz
>>>>>>>> with a Nesdr key;
>>>>>>>> the sdr.py file is from January 22nd
>>>>>>>>
>>>>>>>> Il giorno domenica 7 agosto 2022 alle 15:32:29 UTC+2 Peppe ha
>>>>>>>> scritto:
>>>>>>>>
>>>>>>>>> Hello everyone, I ask you for a little help to insert the uv and
>>>>>>>>> radiation sensors of a whx080 station into my sensor map.
>>>>>>>>> Here is the result of the sudo rtl_433 -M utc -F json command:
>>>>>>>>>
>>>>>>>>> {"time": "2022-08-07 13:26:39", "model": "Endoffset-WHx080",
>>>>>>>>> "subtype": 2, "uv_sensor_id": 225, "uv_status": "OK", "uv_index ":
>>>>>>>>> 2," lux
>>>>>>>>> ": 32082.000," wm ": 46,972," mic ":" CRC "}
>>>>>>>>>
>>>>>>>>> What is the right line to insert within the weewx.conf sensor map?
>>>>>>>>> thanks for your cooperation and sorry for my bad english
>>>>>>>>>
>>>>>>>> --
>>>>>> You received this message because you are subscribed to a topic in
>>>>>> the Google Groups "weewx-user" group.
>>>>>> To unsubscribe from this topic, visit
>>>>>> https://groups.google.com/d/topic/weewx-user/PohR3wcR1UM/unsubscribe.
>>>>>> To unsubscribe from this group and all its topics, send an email to
>>>>>> [email protected].
>>>>>> To view this discussion on the web visit
>>>>>> https://groups.google.com/d/msgid/weewx-user/e67461ea-3e02-4979-afd2-7191a4cfc043n%40googlegroups.com
>>>>>>
>>>>>> <https://groups.google.com/d/msgid/weewx-user/e67461ea-3e02-4979-afd2-7191a4cfc043n%40googlegroups.com?utm_medium=email&utm_source=footer>
>>>>>> .
>>>>>>
>>>>> --
>> You received this message because you are subscribed to a topic in the
>> Google Groups "weewx-user" group.
>> To unsubscribe from this topic, visit
>> https://groups.google.com/d/topic/weewx-user/PohR3wcR1UM/unsubscribe.
>> To unsubscribe from this group and all its topics, send an email to
>> [email protected].
>>
> To view this discussion on the web visit
>> https://groups.google.com/d/msgid/weewx-user/11d088ca-4d0d-4979-9558-9dbdab25bf7dn%40googlegroups.com
>>
>> <https://groups.google.com/d/msgid/weewx-user/11d088ca-4d0d-4979-9558-9dbdab25bf7dn%40googlegroups.com?utm_medium=email&utm_source=footer>
>> .
>>
>
--
You received this message because you are subscribed to the Google Groups
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email
to [email protected].
To view this discussion on the web visit
https://groups.google.com/d/msgid/weewx-user/c501e012-a2ce-4ed8-a65b-e8755ed1a47fn%40googlegroups.com.