We had a similar problem years ago. We use PowerDsine midspan power inserters 
for our AP power (they come in 6, 12, & 24-port versions so they are cheaper 
than buying power for a whole Cisco switch or blade when only a few ports need 
power; management is also easy via a Web interface). In order for them to power 
the old 1200 APs, we had to buy a special dongle from PowerDsine to make them 
work. You may have the same issue.

Call or write offline if you have any questions about this.


-jcw                             [cid:[email protected]]

-------------------------------------
John Watters    UA: OIT  205-348-3992

________________________________
From: The EDUCAUSE Wireless Issues Constituent Group Listserv 
[mailto:[email protected]] On Behalf Of Taillon II, Kendall
Sent: Monday, August 15, 2011 1:57 PM
To: [email protected]
Subject: [WIRELESS-LAN] 1200 Series AP's on a newer 2960s Cisco switch using POE

We are in the middle of adding new 2960s Cisco switches to are edge. When 
connecting our old 1200 series AP's to the switch via POE, the switch interface 
 just keeps flashing. Is this because the old AP's use the old pre-standard 
POE? Our new 1142 series AP's connect just fine.  Is there any way to have the 
older AP's use the newer POE through the switch port?

Ken Taillon
Network Administrator
Wesleyan University
Middletown, CT
860-685-5657

********** Participation and subscription information for this EDUCAUSE 
Constituent Group discussion list can be found at 
http://www.educause.edu/groups/.

**********