Ali,

I see. So, you just need to go http://community.elphel.com/bootblock393/ again
and put the correct data to make 5MPx work. See the attached image.
In short - in the AUX Board table - make sure, *Application* field is *MT9P006
*, and the *Application mode* is *15 *. Then hit "PROGRAM AUX" - it's slow,
so wait a bit (10 sec?). Then "READ AUX" to check the changes were made.

Then reboot the camera. And it should work. If not, please send the
autocampars log again.

I want to back up the micro-SD card but it dose not mount on any OS; how to
> can I do it?

It will mount in any Linux OS. Simply copying the files will not work - you
need raw cloning - please, read about "dd"-utility.
If you have Windows only then it should see the BOOT partition - it's FAT.

Regards,
Oleg



On Tue, Oct 20, 2020 at 6:04 AM ali tamimi <tamimial...@gmail.com> wrote:

>
> Oleg,
> Everything is OK with "14 Mpix" sensor; but when I connect the "5 Mpix"
> no picture is seen at all. I'm sure that there is no problem with cable(it
> works well with "14 Mpix" sensor ). The micro-SD card marked "5MPx" is also
> insert to the slot too. I put the log files below.
> And another question. I want to back up the micro-SD card but it dose not
> mount on any OS; how to can I do it?
>
> *log files:*
> *The "Read AUX" output:*
> <board>
> <brand>Elphel</brand>
> <model>10389</model>
> <rev>B</rev>
> <serial>F80008</serial>
> <time>1603185256</time>
> <app>Eyesis4pi393</app>
> <mode>1001</mode>
> </board>
>
> *The "autocampars.log" :*
> root@elphel393:~# cat /var/log/autocampars.log
> 00014.09 autocampars: initializing state file /var/volatile/state/camera
> 00014.27 autocampars: Application - Eyesis4pi393, mode: 1001
>
> 00014.30 autocampars: Processing camera state: BOOT
> 00014.33 autocampars: Got sensor map from sysfs:
> 0: mt9p006, none, none, none
> 1: mt9p006, none, none, none
> 2: mt9p006, none, none, none
> 3: mt9p006, none, none, none
> 00014.35 autocampars: Active sensor ports: 0,1,2,3 master_port = 0
> 00014.38 autocampars: Sensors map read from the sysfs: [mt9p006, none,
> none, none],[mt9p006, none, none, none],[mt9p006, none, none,
> none],[mt9p006, none, none, none]
> 00014.41 autocampars: Parsed existing ini file
> 00014.43 autocampars: get_application_mode()->1013623
> 00014.46 autocampars: Parsed existing ini file
> 00014.49 autocampars: Detecting sensors for Eyesis4pi393
> 00014.51 autocampars: Got --init command, initialization was not
> completed, just continue
> 00014.54 autocampars: detect_camera()
> 00014.56 autocampars: detect_camera():
> 0: mt9p006, none, none, none
> 1: mt9p006, none, none, none
> 2: mt9p006, none, none, none
> 3: mt9p006, none, none, none
> 00014.59 autocampars: ports:0, 1, 2, 3
> 00014.62 autocampars: boot
> 00014.64 autocampars: Parsed existing ini file
> 00014.67 autocampars: Using sensor mask 0xf7777
> 00016.95 autocampars: Setting sensors/multiplexers power
> 00016.98 autocampars: set_eyesis_power_control()=>Array
> (
>     [result] => OK
>     [retval] => 0
> )
>
> 00017.00 autocampars: GLOBALS['camera_state_arr']=>Array
> (
>     [exit_stage] =>
>     [state] => BOOT
>     [rev10389] => B
>     [application] => Eyesis4pi393
>     [mode] => 1001
>     [max_frame_time] => 300000
>     [is_slave] => 1
>     [eyesis_top] => 1
>     [is_eyesis] => 1
>     [eyesis_power] => 1
>     [max_latency] => 5
> )
>
> 00017.03 autocampars: Current state: BOOT
> 00017.06 autocampars: This is a slave camera - waiting for master to
> contol next steps
> 00017.08 autocampars: Log file saved as /var/log/autocampars.log
> 00017.11 autocampars: ----------------------------------------------
> root@elphel393:~#
>
> On Mon, Oct 19, 2020 at 10:18 PM Oleg <support-list@support.elphel.com>
> wrote:
>
>> Ali,
>>
>> 1. Please send the /var/log/autocampars.log. It can help to rule out a
>> possible misconfiguration. If everything is correct then one can assume
>> it's a bad cable.
>>
>> 2. (just want to double check your configuration) Go
>> http://community.elphel.com/bootblock393/, make sure the ip address in
>> the 1st table is correct, then click "Read AUX" in the "AUX board
>> (10389)"-table - what's the output?
>>
>> Regards,
>> Oleg
>>
>> On Mon, Oct 19, 2020 at 9:21 AM Elphel Support <
>> support-list@support.elphel.com> wrote:
>>
>>> Hello Ali,
>>>
>>> There should be no problems with impedance matching, we tested both
>>> types of sensors with up to 450mm cables (for ectremely long cable
>>> programmatic phase adjustment may be needed). And the cables are the same
>>> for both serial (14MPix) and parallel (5MPix).
>>>
>>> Andrey
>>>
>>>
>>> ---- On Mon, 19 Oct 2020 05:33:14 -0600 *ali tamimi
>>> <tamimial...@gmail.com <tamimial...@gmail.com>>* wrote ----
>>>
>>> Hello Oleg
>>> yes, i can 'ssh' to camera and also can send
>>> the/var/log/autocampars.log. The microSD card marked "5MPx" is also insert
>>> to the slot.
>>> We opened the camera. When closing the sensor cable was pressed slightly
>>> and deformed. I guess the cable is damaged. In the parts list of the "5
>>> MPx" sensor, FFC cable with model number 050-30-51B, is provided. But
>>> by connecting this cable, the sensor is not detected eaither.The
>>> connection photo is sent in the attachment. Could there be a problem
>>> with the cable (for example, impedance matching, etc.)?
>>>
>>> On Sun, Oct 18, 2020 at 11:23 AM Oleg <support-list@support.elphel.com>
>>> wrote:
>>>
>>> Hello Ali,
>>>
>>> Can you 'ssh' to the camera? Could you send the /var/log/autocampars.log?
>>>
>>> ~$ ssh root@192.168.0.9 <http://mailto:root@192.168.0.9>
>>> ~# cat /var/log/autocampars.log
>>>
>>>
>>> Or if you use minicom - send the boot log.
>>>
>>> If I remember right you should have a microSD card marked a "5MPx" - the
>>> camera autoboots from the card - I suggest you try the card first. And the
>>> only thing you will need is to set "MT9*P*006" from the bootblock393
>>> page.
>>>
>>> Regards,
>>> Oleg
>>>
>>> On Sun, Oct 18, 2020 at 7:56 AM ali tamimi <tamimial...@gmail.com>
>>> wrote:
>>>
>>> Hello
>>> We have provided your product 10393. Your camera is very well designed
>>> and made. Thank you for your good products and complete documentation
>>> and your support.
>>> Sensor installed on 10393 is a 14-megapixel sensor (10398) "mt9f002" by
>>> default that Works well. We also bought the 10338 "mt9006" sensor. By
>>> replacing the sensors, the new one is not detectable and no image is
>>> seen.
>>> We downloaded the latest firmware, although the default sensor is
>>> "mt9006"  in the manual, the "devicetree.dtb" replacement process was
>>> performed according to the instructions,10393 nand flash was programmed
>>> but the sensor is not detected again.The image of error in web
>>> interface sent in the attachment. Thanks for your support in solving
>>> the problem.
>>> _______________________________________________
>>> Support-list mailing list
>>> Support-list@support.elphel.com
>>>
>>> http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com
>>>
>>>
>>> _______________________________________________
>>> Support-list mailing list
>>> Support-list@support.elphel.com
>>>
>>> http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com
>>>
>>>
>>>
>>> _______________________________________________
>>> Support-list mailing list
>>> Support-list@support.elphel.com
>>>
>>> http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com
>>>
>>
>>
>> --
>> Best regards,
>> Oleg Dzhimiev
>> Electronics Engineer
>> phone: +1 801 783 5555 x124
>> Elphel, Inc.
>>
> _______________________________________________
> Support-list mailing list
> Support-list@support.elphel.com
> http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com
>


-- 
Best regards,
Oleg Dzhimiev
Electronics Engineer
phone: +1 801 783 5555 x124
Elphel, Inc.
_______________________________________________
Support-list mailing list
Support-list@support.elphel.com
http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com

Reply via email to