Technically you shouldn't bend a radius greater than six inches, turn more than a 90 degree angle, or place ground within six inches of any conductor that is not a ground. On May 12, 2015 7:03 PM, "Tyler Treat" <[email protected]> wrote:
> Sharp. Nice and clean. Love it. > > Not that I’d ever question your work, but Is it considered copacetic to > coil the ground like that? > > > > *From:* Af [mailto:[email protected]] *On Behalf Of *Jaime Solorza > *Sent:* Tuesday, May 12, 2015 10:01 PM > *To:* Animal Farm > *Subject:* [AFMUG] Stand off mount on uneven surface > > > > Bolt in anchors 5 inch...a 3/4 nut flush to face on each of 4 bolts. > Install mount. Then washer , pressure washer and nut. Levels on mount. > Then adjust back nut until mount is level. Luckily didn't need too much to > get..tighten up and complete installation. 6 more to go. > Jaime Solorza >