All 450i radios (except the 900SM) is 802.3at compliant. Then I guess the question is, will the CTM port do sync-over-power in 3at mode? My guess is no. You'll have to do the pin swapping that Cambium recommends for the CMM4. Then tell your CTM that the port is 320/430 mode. But you won't get gigabit obviously. Not like that matters on the 900 though.

On 12/3/2015 12:14 PM, Ken Hohhof wrote:
I’m thinking more along the lines that my first test site for 450i 900 MHz will be at a tower where I already have a CTM-2 master + slave and if it works out it will be replacing a 900 FSK sector that is currently powered from the CTM-2.
So I was kind of hijacking your thread.
*From:* Sam Lambie <mailto:[email protected]>
*Sent:* Thursday, December 03, 2015 12:08 PM
*To:* [email protected] <mailto:[email protected]>
*Subject:* Re: [AFMUG] 450i and Syncinjectors
Would be nice if that did sync on all modes. But I already have a fair amount of PF gear at this site. And I like it. On Thu, Dec 3, 2015 at 11:06 AM, Ken Hohhof <[email protected] <mailto:[email protected]>> wrote:

    Hmmmm, what about a Last Mile Gear CTM-2?
    It has 5 different modes.  A is for 29.5V Cambium, B is for 56V
    Cambium 320 and 430, and then there are 3 modes C/D/E for various
    forms of 802.3at.  Should I assume one of these will power a 450i
    AP?  What about timing, the documentation is not clear whether
    these modes can do sync.
    *From:* Sam Lambie <mailto:[email protected]>
    *Sent:* Thursday, December 03, 2015 11:46 AM
    *To:* [email protected] <mailto:[email protected]>
    *Subject:* Re: [AFMUG] 450i and Syncinjectors
    I assume that I will need a separate SyncInjector for the 450i
    then as I have 450's in the mix as well. Would a Meanwell SD
    120-48 PSU Work?
    On Thu, Dec 3, 2015 at 10:42 AM, Josh Baird <[email protected]
    <mailto:[email protected]>> wrote:

        The SyncInjector can take up to ~57V (ignore the label).  You
        will need to power it with 48V to power the 450i.
        There are problems with cable distance on SyncInjectors prior
        to H1 (I beileve).  Depending on your cable distance, you may
        or may not see an issue from what I understand.
        Josh
        On Thu, Dec 3, 2015 at 12:41 PM, Sam Lambie
        <[email protected] <mailto:[email protected]>> wrote:

            After looking at some of the earlier posts, I can't really
            determine if I can use the 450i AP on a gigabit
            syncinjector. It appears that it want a 48vdc power
            supply. What is the best way to set this up? Or will it
            actually accept the 29 vdc power supply on the SyncInjector?
            Sam
-- -- *Sam Lambie*
            Taosnet Wireless Tech.
            575-758-7598 <tel:575-758-7598> Office
            www.Taosnet.com <http://www.newmex.com>



-- -- *Sam Lambie*
    Taosnet Wireless Tech.
    575-758-7598 <tel:575-758-7598> Office
    www.Taosnet.com <http://www.newmex.com>



--
--
*Sam Lambie*
Taosnet Wireless Tech.
575-758-7598 Office
www.Taosnet.com <http://www.newmex.com>

Reply via email to