Mike K2MK wrote: >Hi Ian, > >My 5 year old SteppIR controller works fine at 38400 bps. > >73, >Mike K2MK
The one I originally used must have been a very early model, then, because that definitely was 19200 max. With my present SDA-100, everything can be set to 38400. >Ian White GM3SEK wrote >> >> The older SteppIR controller can only handle up to 19200 bps. That speed >> must be manually configured in all three devices - the SteppIR >> controller, the computer and the P3 - and the SteppIR controller MUST be >> connected at the INput of the P3 (NOT to the K3) >> >> The connection between the P3 and the K3 will always be automatically >> reconfigured to 38400 bps (regardless of the manual configuration >> setting in the K3) so an older SteppIR controller cannot read the >> traffic at this speed. >> >> The newer SteppIR SDA-100 controller can handle 38400 bps so it could be >> connected to either the K3 or the P3, but again this speed must be >> manually configured in all three device -- 73 from Ian GM3SEK http://www.ifwtech.co.uk/g3sek ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html