Mike K2MK wrote:
>Hi Ian,
>
>My 5 year old SteppIR controller works fine at 38400 bps.
>
>73,
>Mike K2MK

The one I originally used must have been a very early model, then, 
because that definitely was 19200 max. With my present SDA-100, 
everything can be set to 38400.



>Ian White GM3SEK wrote
>>
>> The older SteppIR controller can only handle up to 19200 bps. That speed
>> must be manually configured in all three devices - the SteppIR
>> controller, the computer and the P3 - and the SteppIR controller MUST be
>> connected at the INput of the P3 (NOT to the K3)
>>
>> The connection between the P3 and the K3 will always be automatically
>> reconfigured to 38400 bps (regardless of the manual configuration
>> setting in the K3) so an older SteppIR controller cannot read the
>> traffic at this speed.
>>
>> The newer SteppIR SDA-100 controller can handle 38400 bps so it could be
>> connected to either the K3 or the P3, but again this speed must be
>> manually configured in all three device


-- 

73 from Ian GM3SEK
http://www.ifwtech.co.uk/g3sek
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to