On 21 April 2017 at 11:45, Valerio Bellizzomi <vale...@selnet.org> wrote:
> The X stepgen is show as 5 in the tab, and as
> hm2_5i25.0.stepgen.05.counts in the test window, and it is changing
> while I press the movement button

I think this is the problem.

https://github.com/LinuxCNC/hostmot2-firmware/blob/master/src/PIN_7I76x2_34.vhd

Shows stepgen.05 to be on the expansion connector, not the DB25.

Configure the X axis to be on Connector 3.

-- 
atp
"A motorcycle is a bicycle with a pandemonium attachment and is
designed for the especial use of mechanical geniuses, daredevils and
lunatics."
— George Fitch, Atlanta Constitution Newspaper, 1916

------------------------------------------------------------------------------
Check out the vibrant tech community on one of the world's most
engaging tech sites, Slashdot.org! http://sdm.link/slashdot
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users