On Fri, 2017-04-21 at 11:56 +0100, andy pugh wrote: > On 21 April 2017 at 11:45, Valerio Bellizzomi <vale...@selnet.org> wrote: > > The X stepgen is show as 5 in the tab, and as > > hm2_5i25.0.stepgen.05.counts in the test window, and it is changing > > while I press the movement button > > I think this is the problem. > > https://github.com/LinuxCNC/hostmot2-firmware/blob/master/src/PIN_7I76x2_34.vhd > > Shows stepgen.05 to be on the expansion connector, not the DB25. > > Configure the X axis to be on Connector 3. >
Thanks, and I have another question: how do we call the test window from the command line ? ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, Slashdot.org! http://sdm.link/slashdot _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users