----[Please read http://ercoupers.com/disclaimer.htm before following any
advice in this forum.]----


on 11/04/03 9:35 PM, [EMAIL PROTECTED] at [EMAIL PROTECTED] wrote:

> Needs some help
> Does anyone happen to know the correct arm and moment for the Alon A2
header
> tanks and the two wing tanks?  Iam trying to setup the weight and
balance in a
> new flight planning program and the info that I have in my Owners Manual
> doesn't make sense as it doesn't seperate the fuslege and the wing
tanks.  The
> header tank is forward of the CG and the wing tanks are , I believe ,
behind
> the CG .  My OM lumps all tanks together (24 gal) rather then three
entrys one
> for each tank , which I believe gives an incorrect Weight & Balance
result.
> Any help would be aprecitated
> Bob Bullock
> N5621F
> Maryland


Yo, Bob

The Weight and Balance form at the end of Ercoupe Service Memorandum #23
shows the fuselage tank fuel as weighing 30 lbs (5 gal. at six lbs./gal.)
at
an arm of 7 for a horizontal moment of 210.  Fuel in each wing tank is
individually shown as weighing 54 lbs at an arm of 25 for a horizontal
moment of 1350.  

This memorandum came out while production coupes had ternplate tanks, but
ERCO was calculating 9 gal. capacity wing tanks.  I believe your nose tank
is six gallons for 36 lbs and a horizontal moment of 252.  In both forward
and rearward C. G. calculations your header tank should be full and ERCO
used a minimum wing tank fuel weight of 42 lbs.  Later on, they used a
combined minimum fuel of 12 gallons for such calculations.

Any aircraft's weight and balance changes as fuel is burned.  I agree you
can't accurately calculate the minimum fuel C. G. lumping all together.

Regards,

WRB 

==========================================================================
====
To leave this forum go to: http://ercoupers.com/lists.htm
Search the archives on http://escribe.com/aviation/coupers-tech/


<<attachment: winmail.dat>>