On Fri Oct 10 19:18:22 PDT 2014 [email protected] said:
>I've been looking at using LEAF batteries also.  Since I'm planning a lower
>voltage system than the LEAF, I'm planning on paralleling groups of three 
>packs.
>I noticed that the packs bring out the center tap between the two series sets 
>of
>cells and I'm planning on paralleling the center connections as well as the 
>ends
>of the string, so forcing the cells in the three packs to stay balanced.

I quite purposely did NOT parallel the center connections.  This allows the BMS 
to monitor EVERY cell (pair) to detect problems earlier.


--

Bobcats and Cougars, oh my!  http://john.casadelgato.com/Pets
_______________________________________________
UNSUBSCRIBE: http://www.evdl.org/help/index.html#usub
http://lists.evdl.org/listinfo.cgi/ev-evdl.org
For EV drag racing discussion, please use NEDRA 
(http://groups.yahoo.com/group/NEDRA)

Reply via email to