Barry Oppenheim via EV wrote:
Slightly OT, does anyone have a good way to add manual function to a HV
contactor?  It would be nice to be able to turn on the DC/DC converter
manually in case of 12V failure without having to rig a jumper.  I vaguely
remember that one of the OEM EV's had such a button in the glove
compartment for that exact situation.

The simplest way is probably to add a manual switch to turn on the DC/DC. Just be sure it's DC rated for your pack voltage. Perhaps the simplest source of high voltage DC switches are antique 120/240v DC household switches. These are the ones that made a loud "clack" when you switched them on/off.

Or, add an Anderson connector to act as a switch. Plug in a mating Anderson that just has a shorting jumper.
--
"IC chip performance doubles every 18 months." -- Moore's law
"The speed of software halves every 18 months." -- Gates' law
--
Lee Hart, 814 8th Ave N, Sartell MN 56377, www.sunrise-ev.com