Thanks Ed, but being new at HCD etc. Could you describe a procedure or something along the line which could follow. It's no problem getting the IODF05, from test over to the Prod system and cataloging it. It's just I don't quit understand what to do next. Just IPL Prod point the IPLPARMS on the HMC to the place where IODF05 if is located?
Ed Finnell <[EMAIL PROTECTED]> wrote: In a message dated 7/2/2006 2:26:27 P.M. Central Standard Time, [EMAIL PROTECTED] writes: How do I generate 2 OS configurations, one for test and one for prod lpars to use IODF05. Any help will be greatly appreciated. >> LOADxx specifies parms for IODF and a volser. IODF does not have to be CATLOG'ed for IPL but does for DYNAMIC activation. You also said DASD was not shared between test and production. What I'd do is backup IODF05 from test to tape and restore it to PROD on the same volser as current. Then I'd try DYNAMIC activation on PROD for the cataloged version of IODF05 with TEST option and see what happened? ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html --------------------------------- Do you Yahoo!? Everyone is raving about the all-new Yahoo! Mail Beta. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html