Thanks Ed, but being new at HCD etc. Could you describe a procedure or 
something along the line which could follow. 
   
  It's no problem getting the IODF05, from test over to the Prod system and 
cataloging it. It's just I don't quit understand what to do next.
   
  Just IPL Prod point the IPLPARMS on the HMC to the place where IODF05 if is 
located?
  

Ed Finnell <[EMAIL PROTECTED]> wrote:
  
In a message dated 7/2/2006 2:26:27 P.M. Central Standard Time, 
[EMAIL PROTECTED] writes:

How do I generate 2 OS configurations, one for test and one for prod lpars 
to use IODF05.

Any help will be greatly appreciated.



>>
LOADxx specifies parms for IODF and a volser. IODF does not have to be 
CATLOG'ed for IPL but does for DYNAMIC activation. You also said DASD was not 
shared between test and production. What I'd do is backup IODF05 from test to 
tape and restore it to PROD on the same volser as current. Then I'd try DYNAMIC 
activation on PROD for the cataloged version of IODF05 with TEST option and 
see what happened? 

----------------------------------------------------------------------